Applications of pixel detectors to electron microscopy

被引:4
作者
Faruqi, AR [1 ]
Cattermole, DM [1 ]
Raeburn, C [1 ]
机构
[1] MRC, Mol Biol Lab, Cambridge CB2 2QH, England
关键词
pixel detectors; electron microscopy; imaging; electron crystallography; semiconductor detector;
D O I
10.1016/S0168-9002(03)01908-9
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
There is a compelling need for developing high performance electronic detectors due to the increasing levels of automation in electron microscopy and requirements for large numbers of new biological structures to be studied. CCD-based detectors, which have many desirable properties, have become very well established, particularly, for electron crystallography. There are, however, some shortcomings in the present generation of CCD detectors, e.g. poor spatial resolution relative to film, which make them less attractive for high-resolution imaging. Direct detection semiconductor detectors, which avoid the intermediate step of energy conversion into visible light, offer the prospect of improved resolution, though with certain other limitations. Preliminary results obtained by imaging 60 and 120 keV electrons in Medipix1, a hybrid pixel detector (64 x 64 pixels, 170 mum square) developed by the Medipix collaboration, are presented. A number of improvements to the design would lead to a viable detector for electron microscopy. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:310 / 317
页数:8
相关论文
共 16 条
[1]  
BARDELLONI G, 2000, P IEEE NUCL SCI S ME, P57
[2]  
BOETTCHER B, 1997, NATURE, V386, P88
[3]   A readout chip for a 64 x 64 pixel matrix with 15-bit single Photon Counting [J].
Campbell, M ;
Heijne, EHM ;
Meddeler, G ;
Pernigotti, E ;
Snoeys, W .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) :751-753
[4]   Cooled CCD detector with tapered fibre optics for recording electron diffraction patterns [J].
Faruqi, AR ;
Henderson, R ;
Subramaniam, S .
ULTRAMICROSCOPY, 1999, 75 (04) :235-250
[5]   Cooled CCD camera with tapered fibre optics for electron microscopy [J].
Faruqi, AR ;
Andrews, HN .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 392 (1-3) :233-236
[6]   CCD detectors in high-resolution biological electron microscopy [J].
Faruqi, AR ;
Subramaniam, S .
QUARTERLY REVIEWS OF BIOPHYSICS, 2000, 33 (01) :1-27
[7]   Evaluation of a hybrid pixel detector for electron microscopy [J].
Faruqi, AR ;
Cattermole, DM ;
Henderson, R ;
Mikulec, B ;
Raeburn, C .
ULTRAMICROSCOPY, 2003, 94 (3-4) :263-276
[8]   Digital detectors for electron microscopy [J].
Faruqi, AR ;
Cattermole, DM .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 478 (1-2) :88-94
[9]   A tiled CCD detector with 2 x 2 array and tapered fibre optics for electron microscopy [J].
Faruqi, AR ;
Andrews, HN ;
Cattermole, DM ;
Stubbings, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 477 (1-3) :137-142
[10]   MODEL FOR THE STRUCTURE OF BACTERIORHODOPSIN BASED ON HIGH-RESOLUTION ELECTRON CRYOMICROSCOPY [J].
HENDERSON, R ;
BALDWIN, JM ;
CESKA, TA ;
ZEMLIN, F ;
BECKMANN, E ;
DOWNING, KH .
JOURNAL OF MOLECULAR BIOLOGY, 1990, 213 (04) :899-929