Solid-cantact electrochemical polyion sensors for monitoring peptidase activities

被引:25
作者
Fordyce, Katherine [1 ]
Shvarev, Alexey [1 ]
机构
[1] Oregon State Univ, Dept Chem, Corvallis, OR 97331 USA
关键词
D O I
10.1021/ac701775n
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report here on improved solid-contact electrochemical polyion sensors for the detection of polyion protamine. The polymeric membrane sensors were fabricated with a conducting polymer as an ion-electron transduction layer. We observed. that decreasing the magnitude of the applied current pulse caused a significant improvement of the sensor sensitivity to low protamine levels. The protamine sensors exhibited a stable and reversible response to protamine concentrations ranging from 0.05 to 30 mg L-1. The sensors were used for monitoring peptidase activities utilizing galvanostatically controlled solid-contact membrane sensors. The polyion protamine was used as a substrate to detect the activity of the protease trypsin. The enzyme activity was continuously monitored by measuring the protamine concentration as it is cleaved by enzyme into smaller fragments to which the sensor is less sensitive. In the presence of a given level of protamine the initial rate of reaction can be linearly related to the trypsin activity within a 0-5 U mL(-1) concentration range. The interference with the enzymatic reaction product arginine was specifically examined.
引用
收藏
页码:827 / 833
页数:7
相关论文
共 23 条
[11]   TRYPSIN ACTIVITY - A NEW MARKER OF ACUTE ALCOHOLIC PANCREATITIS [J].
LEMOINE, O ;
DEVASTER, JM ;
DEVIERE, J ;
THIRY, P ;
CREMER, M ;
OOMS, HA .
DIGESTIVE DISEASES AND SCIENCES, 1994, 39 (12) :2634-2638
[12]   ELECTROCHEMICAL SENSOR FOR HEPARIN - FURTHER CHARACTERIZATION AND BIOANALYTICAL APPLICATIONS [J].
MA, SC ;
YANG, VC ;
FU, B ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1993, 65 (15) :2078-2084
[13]   HEPARIN-RESPONSIVE ELECTROCHEMICAL SENSOR - A PRELIMINARY-STUDY [J].
MA, SC ;
YANG, VC ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1992, 64 (06) :694-697
[14]   Renewable pH cross-sensitive potentiometric heparin sensors with incorporated electrically charged H+ ionophores [J].
Mathison, S ;
Bakker, E .
ANALYTICAL CHEMISTRY, 1999, 71 (20) :4614-4621
[15]  
Munoz A, 2000, AM FAM PHYSICIAN, V62, P164
[16]   General description of the simultaneous response of potentiometric ionophore-based sensors to ions of different charge [J].
Nägele, M ;
Bakker, E ;
Pretsch, E .
ANALYTICAL CHEMISTRY, 1999, 71 (05) :1041-1048
[17]   Pulsed galvanostatic control of solid-state polymeric ion-selective electrodes [J].
Perera, Hasini ;
Fordyce, Katherine ;
Shvarev, Alexey .
ANALYTICAL CHEMISTRY, 2007, 79 (12) :4564-4573
[18]  
Ramamurthy N, 1998, CLIN CHEM, V44, P606
[19]   Photoresponsive ion-selective optical sensor [J].
Shvarev, A .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (22) :7138-7139
[20]   Response characteristics of a reversible electrochemical sensor for the polyion protamine [J].
Shvarev, A ;
Bakker, E .
ANALYTICAL CHEMISTRY, 2005, 77 (16) :5221-5228