Bismuth film electrode for simultaneous adsorptive stripping analysis of trace cobalt and nickel using constant current chronopotentiometric and voltammetric protocol

被引:111
作者
Hutton, EA
Hocevar, SB
Ogorevc, B
Smyth, MR
机构
[1] Natl Inst Chem, Analyt Chem Lab, SI-1000 Ljubljana, Slovenia
[2] Dublin City Univ, Natl Ctr Sensor Res, Dublin 9, Ireland
关键词
bismuth electrode; adsorptive stripping chronopotentiometry; cobalt; nickel; dimethylglyoxime;
D O I
10.1016/S1388-2481(03)00177-2
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Bismuth film electrode (BiFE) is presented as a promising alternative to mercury electrodes for the Simultaneous determination of trace cobalt and nickel in non-deoxygenated solutions. The preplated BiFE was employed under adsorptive stripping constant current chronopotentiometric and adsorptive stripping voltammetric conditions in the presence of dimethylglyoxime complexing agent. BiFE exhibited well-defined and undistorted signals with favorable overall resolution for cobalt and nickel cations, with the signals for both metal cations being practically independent of each other. The stripping performance of BiFE is characterized by good reproducibility (RSE) 1.4% for Co(II), and 4.3%) for Ni(II)), low detection limits of 0.08 mugl(-1) for Co(II) and 0.26 mug l(-1) for Ni(II) employing a deposition time of 60 s, in addition to good linearity. The non-toxic character of bismuth imparts the possibility of tailoring disposable and one-shot electrochemical sensors for decentralized environmental, clinical and industrial monitoring of trace cobalt and nickel. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:765 / 769
页数:5
相关论文
共 29 条
[1]   Stripping voltammetry for the determination of trace metal speciation and in-situ measurements of trace metal distributions in marine waters [J].
Achterberg, EP ;
Braungardt, C .
ANALYTICA CHIMICA ACTA, 1999, 400 :381-397
[2]   Electrochemical and spectroscopic investigation of the reduction of dimethylglyoxime at mercury electrodes in the presence of cobalt and nickel [J].
Baxter, LAM ;
Bobrowski, A ;
Bond, AM ;
Heath, GA ;
Paul, RL ;
Mrzljak, R ;
Zarebski, D .
ANALYTICAL CHEMISTRY, 1998, 70 (07) :1312-1323
[3]   Applications, potentialities and limitations of adsorptive stripping analysis on mercury film electrodes [J].
Economou, A ;
Fielden, PR .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1997, 16 (05) :286-292
[4]   DETERMINATION OF NICKEL AND COBALT IN NATURAL-WATERS AND BIOLOGICAL-MATERIAL BY REDUCTIVE CHRONOPOTENTIOMETRIC STRIPPING ANALYSIS IN A FLOW SYSTEM WITHOUT SAMPLE DEOXYGENATION [J].
ESKILSSON, H ;
HARALDSSON, C ;
JAGNER, D .
ANALYTICA CHIMICA ACTA, 1985, 175 (SEP) :79-88
[5]   POTENTIOMETRIC STRIPPING ANALYSIS - A REVIEW [J].
ESTELA, JM ;
TOMAS, C ;
CLADERA, A ;
CERDA, V .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1995, 25 (02) :91-141
[6]  
Flechsig GU, 2002, ELECTROANAL, V14, P192, DOI 10.1002/1521-4109(200202)14:3<192::AID-ELAN192>3.0.CO
[7]  
2-6
[8]  
GALUS Z, 1976, FUNDAMENTALS ELECTRO, P193
[9]  
GIL EP, 1993, FRESEN J ANAL CHEM, V346, P957
[10]  
GIL EP, 1993, FRESEN J ANAL CHEM, V346, P952