MR imaging-guided focused ultrasound surgery of fibroadenomas in the breast: A feasibility study

被引:481
作者
Hynynen, K
Pomeroy, O
Smith, DN
Huber, PE
McDannold, NJ
Kettenbach, J
Baum, J
Singer, S
Jolesz, FA
机构
[1] Harvard Univ, Brigham & Womens Hosp, Sch Med, Dept Radiol, Boston, MA 02115 USA
[2] Harvard Univ, Brigham & Womens Hosp, Sch Med, Dept Surg, Boston, MA 02115 USA
[3] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
关键词
breast neoplasms; MR; therapeutic radiology; therapeutic ultrasound (US); US; fibroadenoma;
D O I
10.1148/radiology.219.1.r01ap02176
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To test the feasibility of noninvasive magnetic resonance (MR) imaging-guided focused ultrasound surgery (FUS) of benign fibroadenomas in the breast. MATERIALS AND METHODS: Eleven fibroadenomas in nine patients under local anesthesia were treated with MR imaging-guided FUS. Based on a T2-weighted definition of target volumes, sequential sonications were delivered to treat the entire target. Temperature-sensitive phase-difference- based MR imaging was performed during each sonication to monitor focus localization and tissue temperature changes. After the procedure, T2-weighted and contrast material-enhanced T1-weighted MR imaging were performed to evaluate immediate and long-term effects. RESULTS: Thermal imaging sequences were improved over the treatment period, with 82% (279 of 342) of the hot spots visible in the last seven treatments. The MR imager was used to measure temperature elevation (12.8 degrees -49.9 degreesC) from these treatments. Eight of the 11 lesions treated demonstrated complete or partial lack of contrast material uptake on posttherapy ii-weighted images. Three lesions showed no marked decrease of contrast material uptake. This lack of effective treatment was most likely due to a lower acoustic power and/or patient movement that caused misregistration. No adverse effects were detected, except for one case of transient edema in the pectoralis muscle 2 days after therapy. CONCLUSION: MR imaging-guided FUS can be performed to noninvasively coagulate benign breast fibroadenomas.
引用
收藏
页码:176 / 185
页数:10
相关论文
共 55 条
[1]   In vivo target-specific delivery of macromolecular agents with MR-guided focused ultrasound [J].
Bednarski, MD ;
Lee, JW ;
Callstrom, MR ;
Li, KCP .
RADIOLOGY, 1997, 204 (01) :263-268
[2]   Quantitative MR temperature monitoring of high-intensity focused ultrasound therapy [J].
Bohris, C ;
Schreiber, WG ;
Jenne, J ;
Simiantonakis, I ;
Rastert, R ;
Zabel, HJ ;
Huber, P ;
Bader, R ;
Brix, G .
MAGNETIC RESONANCE IMAGING, 1999, 17 (04) :603-610
[3]  
Chen L, 1999, J MAGN RESON IMAGING, V10, P146, DOI 10.1002/(SICI)1522-2586(199908)10:2<146::AID-JMRI6>3.0.CO
[4]  
2-C
[5]   HISTOLOGICAL-CHANGES IN RAT-LIVER TUMORS TREATED WITH HIGH-INTENSITY FOCUSED ULTRASOUND [J].
CHEN, LL ;
RIVENS, I ;
TERHAAR, G ;
RIDDLER, S ;
HILL, CR ;
BENSTED, JPM .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (01) :67-74
[6]  
CHUNG A, 1996, P 4 M INT SOC MAGN R, P1738
[7]   Thermal dosimetry of a focused ultrasound beam in vivo by magnetic resonance imaging [J].
Chung, AH ;
Jolesz, FA ;
Hynynen, K .
MEDICAL PHYSICS, 1999, 26 (09) :2017-2026
[8]   Optimization of spoiled gradient-echo phase imaging for in vivo localization of a focused ultrasound beam [J].
Chung, AH ;
Hynynen, K ;
Colucci, V ;
Oshio, K ;
Cline, HE ;
Jolesz, FA .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (05) :745-752
[9]   FOCUSED US SYSTEM FOR MR IMAGING-GUIDED TUMOR ABLATION [J].
CLINE, HE ;
HYNYNEN, K ;
WATKINS, RD ;
ADAMS, WJ ;
SCHENCK, JF ;
ETTINGER, RH ;
FREUND, WR ;
VETRO, JP ;
JOLESZ, FA .
RADIOLOGY, 1995, 194 (03) :731-737
[10]   MR TEMPERATURE MAPPING OF FOCUSED ULTRASOUND SURGERY [J].
CLINE, HE ;
HYNYNEN, K ;
HARDY, CJ ;
WATKINS, RD ;
SCHENCK, JF ;
JOLESZ, FA .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (06) :628-636