Determination of 2-isopropyl thioxanthone and 2-ethylhexyl-4-dimethylaminobenzoate in milk:: comparison of gas and liquid chromatography with mass spectrometry

被引:37
作者
Gil-Vergara, Ana [1 ]
Blasco, Cristina [1 ]
Pico, Yolanda [1 ]
机构
[1] Univ Valencia, Fac Farm, Lab Bromatol, E-46100 Valencia, Spain
关键词
2-isopropyl thioxanthone; 2-ethylhexyl-4-dimethylaminobenzoate; gas chromatography-mass spectrometry; liquid chromatography-tandem mass spectrometry; food analysis; milk;
D O I
10.1007/s00216-007-1482-x
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-mass spectrometry (GC-MS) have been compared for the analysis of 2-isopropyl thioxanthone (ITX) and 2-ethylhexyl-4-dimethylaminobenzoate (EHDAB). Pressurized liquid extraction (PLE) was applied for the extraction of ITX and EHDAB from milk and milk-based beverages. Samples were homogenized with sea sand and anhydrous sodium sulfate, and were extracted with ethyl acetate at 100 degrees C and 10.3X10(6) Pa in one cycle of 10 min at 90% flush. Both, GC-MS and LC-MS/MS were suitable to determine these photoinitiators in the PLE extracts, providing appropriate identification and quantification. The recoveries obtained ranged from 70 to 99% for ITX and from 70 to 95% for EHDAB. These recoveries were equal as those obtained by a conventional liquid-liquid partitioning with acetonitrile and tert-butyl methyl ether-hexane. The quantification limits using GC-MS, based on a signal-to-noise ratio of 10, were 0.5 mu g/L for ITX and 1 mu g/L for EHDAB. The repeatability of the method, as indicated by the relative standard deviations, was within the range 0.9-16.1%. The same parameters calculated using LC-MS/MS result in quantification limits of 0.1 mu g/L for ITX and 0.02 mu g/L for EHDAB and repeatability within the range 5.2-19.4%. These results pointed out that both techniques are appropriate to determine these compounds in food samples. The method was applied to milk and milk-based beverages from different supermarkets. The ITX and EHDAB contents ranged from 2.5 to 325 mu g/L and from 8 to 126 mu g/L, respectively.
引用
收藏
页码:605 / 617
页数:13
相关论文
共 17 条
[11]  
MORLOCK G, 2006, ANAL BIOCH CHEM, V54, P7947
[12]   Migration tests for substrates printed with UV ink systems in aqueous simulants [J].
Papilloud, S ;
Baudraz, D .
PROGRESS IN ORGANIC COATINGS, 2002, 45 (2-3) :231-237
[13]   Analysis of food packaging UV inks for chemicals with potential to migrate into food simulants [J].
Papilloud, S ;
Baudraz, D .
FOOD ADDITIVES AND CONTAMINANTS, 2002, 19 (02) :168-175
[14]   2-Isopropylthioxanthone (2-ITX) in food and food packaging materials on the German market [J].
Rothenbacher, T. ;
Baumann, M. ;
Fuegel, D. .
FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2007, 24 (04) :438-444
[15]   Determination of isopropyl thioxanthone (ITX) in fruit juices by pressurized liquid extraction and liquid chromatography-mass spectrometry [J].
Sagratini, Gianni ;
Manes, Jordi ;
Giardina, Dario ;
Pico, Yolanda .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2006, 54 (20) :7947-7952
[16]  
*SEAL AIR CORP, 2005, REG NEWS AL ITX 2 IS
[17]   Determination of isopropyl-9H-thioxanthen-9-one in packaged beverages by solid-phase extraction clean-up and liquid chromatography with tandem mass spectrometry detection [J].
Sun, Cuilian ;
Chan, Sheot Ham ;
Lu, Dan ;
Lee, Hui Min Wendy ;
Bloodworth, Bosco Chen .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1143 (1-2) :162-167