摘要
Three-dimensional methods for quantifying pulmonary nodule volume at computed tomography (CT) and the effect of imaging variables were studied by using a realistic phantom. Two fixed-threshold methods, a partial-volume method (PVM) and a variable method, were used to calculate volumes of 40 plastic nodules (largest dimension, <5 mm: 20 nodules with solid attenuation and 20 with ground-glass attenuation) of known volume. Tube current times (20 and 120 mAs), reconstruction algorithms (high and low frequency), and nodule characteristics were studied. Higher precision was associated with use of a PVM with predetermined pure nodule attenuation, high-frequency algorithm, and diagnostic CT technique (120 mAs). A PVM is promising for volume quantification and follow-up of nodules.
引用
收藏
页码:864 / 870
页数:7
相关论文
共 32 条
[1]   Evolution of peripheral lung adenocarcinomas: CT findings correlated with histology and tumor doubling time [J].
Aoki, T ;
Nakata, H ;
Watanabe, H ;
Nakamura, K ;
Kasai, T ;
Hashimoto, H ;
Yasumoto, K ;
Kido, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (03) :763-768
[2]   Lung cancer detection in the 21st century: Potential contributions and challenges of emerging technologies [J].
Boiselle, PM ;
Ernst, A ;
Karp, DD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (05) :1215-1221
[3]  
BUSHBERG JT, 1994, ESSENTIAL PHYSICS ME
[4]   Screening for early lung cancer with low-dose spiral CT: Prevalence in 817 asymptomatic smokers [J].
Diederich, S ;
Wormanns, D ;
Semik, M ;
Thomas, M ;
Lenzen, H ;
Roos, N ;
Heindel, W .
RADIOLOGY, 2002, 222 (03) :773-781
[5]  
Fleiss J., 1986, Reliability of measurement: the design and analysis of clinical experiments
[6]   THE EFFECT ON APPARENT SIZE OF SIMULATED PULMONARY NODULES OF USING 3 STANDARD CT WINDOW SETTINGS [J].
HARRIS, KM ;
ADAMS, H ;
LLOYD, DCF ;
HARVEY, DJ .
CLINICAL RADIOLOGY, 1993, 47 (04) :241-244
[7]   Early Lung Cancer Action Project: overall design and findings from baseline screening [J].
Henschke, CI ;
McCauley, DI ;
Yankelevitz, DF ;
Naidich, DP ;
McGuinness, G ;
Miettinen, OS ;
Libby, DM ;
Pasmantier, MW ;
Koizumi, J ;
Altorki, NK ;
Smith, JP .
LANCET, 1999, 354 (9173) :99-105
[8]   Lung cancer screening: Minimum tube current required for helical CT [J].
Itoh, S ;
Ikeda, M ;
Arahata, S ;
Kodaira, T ;
Isomura, T ;
Kato, T ;
Yamakawa, K ;
Maruyama, K ;
Ishigaki, T .
RADIOLOGY, 2000, 215 (01) :175-183
[9]   Brain tumor volume measurement: Comparison of manual and semiautomated methods [J].
Joe, BN ;
Fukui, MB ;
Meltzer, CC ;
Huang, QS ;
Day, RS ;
Greer, PJ ;
Bozik, ME .
RADIOLOGY, 1999, 212 (03) :811-816
[10]   Transthoracic needle biopsy with a coaxially placed 20-gauge automated cutting needle: Results in 122 patients [J].
Klein, JS ;
Salomon, G ;
Stewart, EA .
RADIOLOGY, 1996, 198 (03) :715-720