Statistical dynamic image reconstruction in state-of-the-art high-resolution PET

被引:114
作者
Rahmim, A [1 ]
Cheng, JC
Blinder, S
Camborde, ML
Sossi, V
机构
[1] Johns Hopkins Univ, Sch Med, Dept Radiol, Baltimore, MD 21287 USA
[2] Univ British Columbia, Dept Phys & Astron, Vancouver, BC V6T 1Z1, Canada
[3] Pacific Parkinsons Res Ctr, Vancouver, BC V6T 1Z1, Canada
关键词
D O I
10.1088/0031-9155/50/20/010
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Modem high-resolution PET is now more than ever in need of scrutiny into the nature and limitations of the imaging modality itself as well as image reconstruction techniques. In this work, we have reviewed, analysed and addressed the following three considerations within the particular context of state-of-the-art dynamic PET imaging: (i) the typical average numbers of events per line-of-response (LOR) are now (much) less than unity, (ii) due to the physical and biological decay of the activity distribution, one requires robust and efficient reconstruction algorithms applicable to a wide range of statistics and (iii) the computational considerations in dynamic imaging are much enhanced (i.e., more frames to be stored and reconstructed). Within the framework of statistical image reconstruction, we have argued theoretically and shown experimentally that the sinogram non-negativity constraint (when using the delayed-coincidence and/or scatter-subtraction techniques) is especially expected to result in an overestimation bias. Subsequently, two schemes are considered: (a) subtraction techniques in which an image non-negativity constraint has been imposed and (b) implementation of random and scatter estimates inside the reconstruction algorithms, thus enabling direct processing of Poisson-distributed prompts. Both techniques are able to remove the aforementioned bias, while the latter, being better conditioned theoretically, is able to exhibit superior noise characteristics. We have also elaborated upon and verified the applicability of the accelerated list-mode image reconstruction method as a powerful solution for accurate, robust and efficient dynamic reconstructions of high-resolution data (as well as a number of additional benefits in the context of state-of-the-art PET).
引用
收藏
页码:4887 / 4912
页数:26
相关论文
共 56 条
[1]
Emission image reconstruction for randoms-precorrected PET allowing negative sinogram values [J].
Ahn, ST ;
Fessler, JA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (05) :591-601
[2]
Randoms variance reduction in 3D PET [J].
Badawi, RD ;
Miller, MP ;
Bailey, DL ;
Marsden, PK .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (04) :941-954
[3]
A CONVOLUTION-SUBTRACTION SCATTER CORRECTION METHOD FOR 3D PET [J].
BAILEY, DL ;
MEIKLE, SR .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (03) :411-424
[4]
BARKER WC, 2004, IEEE NSS MIC 2004 RO
[5]
OS-EM and FBP reconstructions at low count rates:: effect on 3D PET studies of [11C] WAY-100635 [J].
Bélanger, MJ ;
Mann, JJ ;
Parsey, RV .
NEUROIMAGE, 2004, 21 (01) :244-250
[6]
Iterative algorithms for deblurring and deconvolution with constraints [J].
Byrne, C .
INVERSE PROBLEMS, 1998, 14 (06) :1455-1467
[7]
Design of a motion-compensation OSEM list-mode algorithm for resolution-recovery reconstruction for the HRRT [J].
Carson, RE ;
Barker, WC ;
Liow, JS ;
Johnson, CA .
2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, :3281-3285
[8]
CARSON RE, 2003, IEEE NUCL SCI S, V5, P19
[9]
QUANTITATION IN POSITRON EMISSION COMPUTED-TOMOGRAPHY .7. A TECHNIQUE TO REDUCE NOISE IN ACCIDENTAL COINCIDENCE MEASUREMENTS AND COINCIDENCE EFFICIENCY CALIBRATION [J].
CASEY, ME ;
HOFFMAN, EJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (05) :845-850
[10]
CHERRY SR, 1993, J NUCL MED, V34, P671