Simultaneous multiple injection in monosegmented flow analysis

被引:23
作者
Brito, VO [1 ]
Raimundo, IM [1 ]
机构
[1] UNICAMP, Inst Quim, BR-13083970 Campinas, SP, Brazil
关键词
monosegmented flow analysis; simultaneous multiple injection; Schlieren effect;
D O I
10.1016/S0003-2670(98)00321-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow approach for simultaneous multiple injection (SMI) in monosegmented flow analysis (MSFA) is described. In this approach, the sample and the reagent (or other solution, such as a diluting fluid) are simultaneously injected into the reaction coil of a monosegmented flow analyser. The monosegment is homogenised while it is carried towards the detector. The sample dilution procedure is not based on a gradient concentration pattern and dilution factors up to 150 were obtained by using hydrodynamic sampling. The system was applied to perform sample dilution in the determination of glucose in blood plasma. The results showed good correlation with those obtained by the Clinical Hospital of UNICAMP. The SMI approach was also applied to add reagent to the sample in nitrite determination in natural water, providing a methodology that has a sampling frequency of 72 h(-1), a relative standard deviation of <2%, at 60 mu g l(-1) N-NO2-, a linear response range up to 260 mu g l(-1) and a 3 s limit of detection of 5 mu g l(-1) N-NO2-. Thus, the sensitivity is close to that of the manual reference method. Recovery tests carried out with sea water samples also showed that MSFA overcomes the Schlieren effect, without needing any special procedure. (C) 1998 Published by Elsevier Science B.V. All rights reserved.
引用
收藏
页码:317 / +
页数:11
相关论文
共 39 条
[31]   CLASSIFICATION AND DEFINITION OF ANALYTICAL METHODS BASED ON FLOWING MEDIA - (IUPAC RECOMMENDATIONS 1994) [J].
VANDERLINDEN, WE .
PURE AND APPLIED CHEMISTRY, 1994, 66 (12) :2493-2500
[32]   Spectrophotometric determination of nitrite in foodstuffs by flow injection analysis [J].
VanStaden, JF ;
Makhafola, MA .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1996, 356 (01) :70-74
[33]   AUTOMATED PREVALVE DILUTION IN FLOW-INJECTION ANALYSIS - THE AUTOMATED-DETERMINATION OF CHLORIDE IN SURFACE, GROUND AND DOMESTIC WATER [J].
VANSTADEN, JF .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1985, 322 (01) :36-41
[34]  
VANSTADEN JF, 1990, FRESEN Z ANAL CHEM, V340, P415
[35]   CASCADE SYSTEM FOR RAPID ONLINE DILUTIONS IN FLOW-INJECTION ANALYSIS [J].
WHITMAN, DA ;
CHRISTIAN, GD .
TALANTA, 1989, 36 (1-2) :205-211
[36]   SIMPLE APPROACH FOR ELIMINATION OF BLANK PEAK EFFECTS IN FLOW-INJECTION ANALYSIS OF SAMPLES CONTAINING TRACE ANALYTE AND AN EXCESS OF ANOTHER SOLUTE [J].
YAMANE, T ;
SAITO, M .
TALANTA, 1992, 39 (03) :215-219
[37]   A SIMPLE PROCEDURE FOR HYDRODYNAMIC INJECTION IN FLOW-INJECTION ANALYSIS APPLIED TO THE ATOMIC-ABSORPTION SPECTROMETRY OF CHROMIUM IN STEELS [J].
ZAGATTO, EAG ;
BAHIA, O ;
GINE, MF ;
BERGAMIN, H .
ANALYTICA CHIMICA ACTA, 1986, 181 :265-270
[38]   COMPENSATION OF THE SCHLIEREN EFFECT IN FLOW-INJECTION ANALYSIS BY USING DUAL-WAVELENGTH SPECTROPHOTOMETRY [J].
ZAGATTO, EAG ;
ARRUDA, MAZ ;
JACINTHO, AO ;
MATTOS, IL .
ANALYTICA CHIMICA ACTA, 1990, 234 (01) :153-160
[39]   AN IMPROVED FLOW-INJECTION DETERMINATION OF NITRITE IN WATERS BY USING INTERMITTENT FLOWS [J].
ZAGATTO, EAG ;
JACINTHO, AO ;
MORTATTI, J ;
BERGAMIN, H .
ANALYTICA CHIMICA ACTA, 1980, 120 (NOV) :399-403