Microfluidic device for capillary electrochromatography-mass spectrometry

被引:75
作者
Lazar, IM [1 ]
Li, LJ [1 ]
Yang, Y [1 ]
Karger, BL [1 ]
机构
[1] Northeastern Univ, Barnett Inst, Boston, MA 02115 USA
关键词
capillary electrochromatography-mass spectrometry; microfluidic device; miniaturization;
D O I
10.1002/elps.200305609
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel microfabricated device that integrates a monolithic polymeric separation channel, an injector, and an interface for electrospray ionization-mass spectrometry detection (ESI-MS) was devised. Microfluidic propulsion was accomplished using electrically driven fluid flows. The methacrylate-based monolithic separation medium was prepared by photopolymerization and had a positively derivatized surface to ensure electroosmotic flow (EOF) generation for separation of analytes in a capillary electrochromatography (CEC) format. The injector operation was optimized to perform under conditions of nonuniform EOF within the microfluidic channels. The ESI interface allowed hours of stable operation at the flow rates generated by the monolithic column. The dimensions of one processing line were sufficiently small to enable the integration of 4-8 channel multiplexed structures on a single substrate. Standard protein digests were utilized to evaluate the performance of this microfluidic chip. Low- or sub-fmol amounts were injected and detected with this arrangement.
引用
收藏
页码:3655 / 3662
页数:8
相关论文
共 42 条
[1]   Microfluidic devises connected to fused-silica capillaries with minimal dead volume [J].
Bings, NH ;
Wang, C ;
Skinner, CD ;
Colyer, CL ;
Thibault, P ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 1999, 71 (15) :3292-3296
[2]   Fritless capillary columns for HPLC and CEC prepared by immobilizing the stationary phase in an organic polymer matrix [J].
Chirica, GS ;
Remcho, VT .
ANALYTICAL CHEMISTRY, 2000, 72 (15) :3605-3610
[3]   Chip-based capillary electrophoresis/mass spectrometry determination of carnitines in human urine [J].
Deng, YZ ;
Henion, J ;
Li, JJ ;
Thibault, P ;
Wang, C ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 2001, 73 (03) :639-646
[4]  
Dulay MT, 2002, J SEP SCI, V25, P3, DOI 10.1002/1615-9314(20020101)25:1/2<3::AID-JSSC3>3.0.CO
[5]  
2-L
[6]   Electroosmosis- and pressure-driven chromatography in chips using continuous beds [J].
Ericson, C ;
Holm, J ;
Ericson, T ;
Hjertén, S .
ANALYTICAL CHEMISTRY, 2000, 72 (01) :81-87
[7]   A microfabricated device for rapid protein identification by microelectrospray ion trap mass spectrometry [J].
Figeys, D ;
Ning, YB ;
Aebersold, R .
ANALYTICAL CHEMISTRY, 1997, 69 (16) :3153-3160
[8]   Capillary columns with in situ formed porous monolithic packing for micro high-performance liquid chromatography and capillary electrochromatography [J].
Gusev, I ;
Huang, X ;
Horváth, C .
JOURNAL OF CHROMATOGRAPHY A, 1999, 855 (01) :273-290
[9]   Sol-gel monolithic columns with reversed electroosmotic flow for capillary electrochromatography [J].
Hayes, JD ;
Malik, A .
ANALYTICAL CHEMISTRY, 2000, 72 (17) :4090-4099
[10]   Surface-alkylated polystyrene monolithic columns for peptide analysis in capillary liquid chromatography-electrospray ionization mass spectrometry [J].
Huang, XA ;
Zhang, S ;
Schultz, GA ;
Henion, J .
ANALYTICAL CHEMISTRY, 2002, 74 (10) :2336-2344