Microfluidic device for capillary electrochromatography-mass spectrometry

被引:75
作者
Lazar, IM [1 ]
Li, LJ [1 ]
Yang, Y [1 ]
Karger, BL [1 ]
机构
[1] Northeastern Univ, Barnett Inst, Boston, MA 02115 USA
关键词
capillary electrochromatography-mass spectrometry; microfluidic device; miniaturization;
D O I
10.1002/elps.200305609
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel microfabricated device that integrates a monolithic polymeric separation channel, an injector, and an interface for electrospray ionization-mass spectrometry detection (ESI-MS) was devised. Microfluidic propulsion was accomplished using electrically driven fluid flows. The methacrylate-based monolithic separation medium was prepared by photopolymerization and had a positively derivatized surface to ensure electroosmotic flow (EOF) generation for separation of analytes in a capillary electrochromatography (CEC) format. The injector operation was optimized to perform under conditions of nonuniform EOF within the microfluidic channels. The ESI interface allowed hours of stable operation at the flow rates generated by the monolithic column. The dimensions of one processing line were sufficiently small to enable the integration of 4-8 channel multiplexed structures on a single substrate. Standard protein digests were utilized to evaluate the performance of this microfluidic chip. Low- or sub-fmol amounts were injected and detected with this arrangement.
引用
收藏
页码:3655 / 3662
页数:8
相关论文
共 42 条
[21]   High-throughput peptide mass mapping using a microdevice containing trypsin immobilized on a porous polymer monolith coupled to MALDI TOF and ESI TOF mass spectrometers [J].
Peterson, DS ;
Rohr, T ;
Svec, F ;
Fréchet, JMJ .
JOURNAL OF PROTEOME RESEARCH, 2002, 1 (06) :563-568
[22]   Capillary array high-performance liquid chromatography of nucleic acids and proteins [J].
Premstaller, A ;
Oefner, PJ ;
Oberacher, H ;
Huber, CG .
ANALYTICAL CHEMISTRY, 2002, 74 (18) :4688-4693
[23]   Generating electrospray from microchip devices using electroosmotic pumping [J].
Ramsey, RS ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 1997, 69 (06) :1174-1178
[24]   Investigations of a sol-gel derived stationary phase for open tubular capillary electrochromatography [J].
Rodríguez, SA ;
Colón, LA .
ANALYTICA CHIMICA ACTA, 1999, 397 (1-3) :207-215
[25]   A fully integrated monolithic microchip electrospray device for mass spectrometry [J].
Schultz, GA ;
Corso, TN ;
Prosser, SJ ;
Zhang, S .
ANALYTICAL CHEMISTRY, 2000, 72 (17) :4058-4063
[26]   Reversed-phase electrochromatography of amino acids and peptides using porous polymer monoliths [J].
Shediac, R ;
Ngola, SM ;
Throckmorton, DJ ;
Anex, DS ;
Shepodd, TJ ;
Singh, AK .
JOURNAL OF CHROMATOGRAPHY A, 2001, 925 (1-2) :251-263
[27]   KINETIC CONTROL OF PORE FORMATION IN MACROPOROUS POLYMERS - FORMATION OF MOLDED POROUS MATERIALS WITH HIGH-FLOW CHARACTERISTICS FOR SEPARATIONS OR CATALYSIS [J].
SVEC, F ;
FRECHET, JMJ .
CHEMISTRY OF MATERIALS, 1995, 7 (04) :707-715
[28]   TEMPERATURE, A SIMPLE AND EFFICIENT TOOL FOR THE CONTROL OF PORE-SIZE DISTRIBUTION IN MACROPOROUS POLYMERS [J].
SVEC, F ;
FRECHET, JMJ .
MACROMOLECULES, 1995, 28 (22) :7580-7582
[29]  
Tang QL, 1999, J MICROCOLUMN SEP, V11, P550, DOI 10.1002/(SICI)1520-667X(1999)11:7<550::AID-MCS8>3.3.CO
[30]  
2-2