In vitro interface and cement mantle analysis of different femur stem designs

被引:28
作者
Gravius, S. [1 ]
Wirtz, D. C. [1 ]
Siebert, C. H. [2 ]
Andereya, St. [3 ]
Mueller-Rath, R. [3 ]
Maus, U. [3 ]
Mumme, T. [3 ]
机构
[1] Univ Hosp Bonn, Dept Orthopaed Surg, D-53125 Bonn, Germany
[2] Annastift Hannover, Clin 1, Dept Orthopaed Surg, D-30625 Hannover, Germany
[3] Univ Hosp Aachen, Dept Orthopaed Surg, D-52074 Aachen, Germany
关键词
total hip arthroplasty; aseptic loosening; cement defects; interface debonding;
D O I
10.1016/j.jbiomech.2008.03.041
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
The aim of this study is to define stem design related factors causing both gaps in the metal-bone cement interface and cracks within the cement mantle. Six different stem designs (Exeter; Lubinus SP II; Ceraver Osteal; Mueller-straight stem; Centega; Spectron EF) (n = 15 of each design) were cemented into artificial femur bones. Ten steins of each design were loaded, while five sterns served as all unloaded control. Physiologically adapted cyclical loading (DIN ISO 7206-4) was performed with a hip simulator. After loading both interfaces and the bone cement itself were analysed regarding gaps and cracks in the cement mantle. Significant differences between the stem designs concerning gaps in the metal-bone cement interface and cracks in the cement mantle became apparent. Additionally, a high correlation between gaps in the metal-bone cement interface and cracks within the cement mantle could be proven. Gaps in the metal-bone cement interface but no cracks within the cement mantle were seen in the unloaded specimens. Differences between the unloaded control groups and the cyclical loaded sterns regarding the longitudinal extension and width of gaps in the metal-bone cement interface were obvious. The designs of cemented femoral stems have an influence on both the quality of the metal-bone cement contact and the failure rate of the cement mantle. Less interface gaps and less cement defects were found with anatomically formed, collared, well-rounded stem designs without undercuttings. (c) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2021 / 2028
页数:8
相关论文
共 25 条
[1]
The rational for cemented stem design [J].
Breusch, SJ ;
Draenert, Y ;
Draenert, K .
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1998, 136 (06) :554-559
[2]
CHARNLEY J, 1961, LANCET, V1, P1129
[3]
ANALYSIS OF FEMORAL COMPONENT STEM DESIGN IN TOTAL HIP-ARTHROPLASTY [J].
CROWNINSHIELD, RD ;
BRAND, RA ;
JOHNSTON, RC ;
MILROY, JC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1980, 62 (01) :68-78
[4]
DRAENERT K, 1999, MANUAL CEMENTING TEC
[5]
Surface pretreatments for medical application of adhesion [J].
Erli, Hans J. ;
Marx, Rudolf ;
Paar, Othmar ;
Niethard, Fritz U. ;
Weber, Michael ;
Wirtz, Dieter C. .
BIOMEDICAL ENGINEERING ONLINE, 2003, 2 (1)
[6]
GARELLICK G, 2000, CLIN ORTHOP RELAT R, V375, P157
[7]
MATHEMATICAL SHAPE OPTIMIZATION OF HIP-PROSTHESIS DESIGN [J].
HUISKES, R ;
BOEKLAGEN, R .
JOURNAL OF BIOMECHANICS, 1989, 22 (8-9) :793-&
[8]
HUISKES R, 1998, CLIN ORTHOP RELAT R, V355, P103
[9]
THE INITIATION OF FAILURE IN CEMENTED FEMORAL COMPONENTS OF HIP ARTHROPLASTIES [J].
JASTY, M ;
MALONEY, WJ ;
BRAGDON, CR ;
OCONNOR, DO ;
HAIRE, T ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (04) :551-558
[10]
FACTORS AFFECTING SURGICAL ALLOY BONE-CEMENT INTERFACE ADHESION [J].
KELLER, JC ;
LAUTENSCHLAGER, EP ;
MARSHALL, GW ;
MEYER, PR .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1980, 14 (05) :639-651