Strontium isotope ratio measurements in prehistoric human bone samples by means of high-resolution inductively coupled plasma mass spectrometry (HR-ICP-MS)

被引:72
作者
Latkoczy, C
Prohaska, T
Stingeder, G
Teschler-Nicola, M
机构
[1] Univ Agr Sci BOKU Vienna, Inst Chem, A-1190 Vienna, Austria
[2] Museum Hist Nat, Dept Anthropol, A-1014 Vienna, Austria
关键词
high-resolution inductively coupled plasma mass spectrometry; strontium isotope ratios; mass bias; deadtime; ancient human bone samples; anthropology;
D O I
10.1039/a800416a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper explores the suitability and application range of a commercially available high-resolution ICP-mass spectrometer (Finnigan MAT Element) in determining strontium isotope ratios of human bone samples. Any paleoanthropological interpretation of such samples requires a highly accurate isotopic ratio determination with a precision of at least 0.1% relative standard deviation (RSD), Thus, optimum instrument operating parameters such as sampling time, scan duration, and instrumental bias factors including mass bias and deadtime, were investigated in an initial step. The instrument itself mas used without modification but equipped with a commercial microconcentric nebulizer, All experiments were performed under clean room conditions with filtered (class 10,000), temperature controlled, and excess pressured air. Complementary mathematical correction methods like deadtime and mass bias corrections, allowed the achievement of a Sr-87/Sr-86 isotope ratio precision below 0.03% (RSD for n = 5), Compared with the certified NIST SRM 987 Strontium Carbonate (Isotopic) value (0.71034 +/- 0.00026), our Sr-87/Sr-86 isotopic ratio revealed a 0.7103 +/- 0.0002 match, This optimized procedure was performed on 7000-year-old human skeleton samples from a Neolithic settlement in Asparn/Schletz, Lower Austria, to determine their stable strontium isotope ratio, Specific isotope patterns thereby shed light on the provenance of single individuals.
引用
收藏
页码:561 / 566
页数:6
相关论文
共 48 条
[1]  
AMMERMANN AJ, 1984, NEOLITHNIC TRANSITIO
[2]   Characterisation and correction of instrumental bias in inductively coupled plasma quadrupole mass spectrometry for accurate measurement of lead isotope ratios [J].
Begley, IS ;
Sharp, BL .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (04) :395-402
[3]   STRONTIUM ISOTOPES IN WEATHERING PROFILES, DEEP-SEA SEDIMENTS, AND SEDIMENTARY ROCKS [J].
DASCH, EJ .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1969, 33 (12) :1521-&
[4]   MEASUREMENTS OF TOTAL LEAD CONCENTRATIONS AND OF LEAD ISOTOPE RATIOS IN WHOLE-BLOOD BY USE OF INDUCTIVELY COUPLED PLASMA SOURCE-MASS SPECTROMETRY [J].
DELVES, HT ;
CAMPBELL, MJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (02) :343-348
[5]   STRONTIUM ISOTOPE CHARACTERIZATION IN THE STUDY OF PREHISTORIC HUMAN-ECOLOGY [J].
ERICSON, JE .
JOURNAL OF HUMAN EVOLUTION, 1985, 14 (05) :503-514
[6]  
ERICSON JE, 1987, STABLE ISOTOPES ECOL, P252
[7]   PERFORMANCE-CHARACTERISTICS OF INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY WITH HIGH-MASS RESOLUTION [J].
FELDMANN, I ;
TITTES, W ;
JAKUBOWSKI, N ;
STUEWER, D ;
GIESSMANN, U .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (09) :1007-1014
[8]  
Fillion N, 1996, CR ACAD SCI II A, V322, P1029
[9]   OPTIMIZATION OF THE MASS SCANNING RATE FOR THE DETERMINATION OF LEAD ISOTOPE RATIOS USING AN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETER [J].
FURUTA, N .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (03) :199-203
[10]   NONSPECTROSCOPIC INTERELEMENT INTERFERENCES IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
GILLSON, GR ;
DOUGLAS, DJ ;
FULFORD, JE ;
HALLIGAN, KW ;
TANNER, SD .
ANALYTICAL CHEMISTRY, 1988, 60 (14) :1472-1474