Electroanalytical determination of the herbicide paraquat in natural water and commercial tea samples with gold electrodes obtained from recordable compact disc

被引:23
作者
De Souza, D [1 ]
Codognoto, L [1 ]
Machado, SAS [1 ]
Avaca, LA [1 ]
机构
[1] Univ Sao Paulo, Inst Quim Sao Carlos, BR-13560970 Sao Carlos, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
gold electrodes; paraquat; square wave voltammetry;
D O I
10.1081/AL-200045163
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work describes the application of gold electrodes constructed from recordable compact discs for the analytical determination of the herbicide paraquat in natural water samples using square wave voltammetry. The detection limit for pure water (laboratory samples) was 21 mug L-1, lower than the EPA limit for drinking water (100 mug L-1). The experimental quantification limit was determined as 73 mug L-l. In polluted creek water samples the detection limit rose to 76.4 mug L-1 and is shown to be dependent on BOD and COD values. Recovery measurements in tea and natural water samples were approximately 95%, which indicates that the methodology can be employed to analyze paraquat in such matrices.
引用
收藏
页码:331 / 341
页数:11
相关论文
共 18 条
[1]  
*AM PUBL HLTH ASS, 1995, STAND METH EX WAT WA
[2]  
[Anonymous], 1996, INT C HARM TECHN REQ
[3]   Square wave voltammetry on boron-doped diamond electrodes for analytical determinations [J].
Codognoto, L ;
Machado, SAS ;
Avaca, LA .
DIAMOND AND RELATED MATERIALS, 2002, 11 (09) :1670-1675
[4]   Electroanalytical study of the paraquat herbicide in aqueous solution by square wave voltammetry using ultramicroelectrodes. [J].
de Souza, D ;
Machado, SAS .
QUIMICA NOVA, 2003, 26 (05) :644-647
[5]  
HU LT, 2000, TALANTA, V53, P443
[6]   Influence of organic matter and surfactants on solid-phase extraction of diquat, paraquat and difenzoquat from waters [J].
Ibanez, M ;
Pico, Y ;
Manes, J .
JOURNAL OF CHROMATOGRAPHY A, 1996, 727 (02) :245-252
[7]   LIMIT OF DETECTION [J].
LONG, GL ;
WINEFORDNER, JD .
ANALYTICAL CHEMISTRY, 1983, 55 (07) :A712-+
[8]   SQUARE-WAVE VOLTAMMETRY OF AN ADSORBED REACTANT [J].
LOVRIC, M ;
KOMORSKYLOVRIC, S .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 248 (02) :239-253
[9]   Electroanalytical determination of the herbicide picloram in natural waters by square wave voltammetry [J].
Massaroppi, MRC ;
Machado, SAS ;
Avaca, LA .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2003, 14 (01) :113-119
[10]   A statistical overview of standard (IUPAC and ACS) and new procedures for determining the limits of detection and quantification: Application to voltammetric and stripping techniques (technical report) [J].
Mocak, J ;
Bond, AM ;
Mitchell, S ;
Scollary, G .