Optimal Choice of Baseline Correction for Multivariate Calibration of Spectra

被引:252
作者
Liland, Kristian Hovde [1 ]
Almoy, Trygve [1 ]
Mevik, Bjorn-Helge [1 ]
机构
[1] Norwegian Univ Life Sci, Dept Chem Biotechnol & Food Sci, N-1432 As, Norway
关键词
Baseline correction; Statistical analysis; Multivariate calibration; Mass spectrometry; Raman spectroscopy; Matrix-assisted laser desorption-ionization time-of-flight spectroscopy; MALDI-TOF; Partial least squares regression; PLSR; Asymmetric least squares; ALS; Robust baseline estimation; Rolling ball algorithm; Wavelets; Local medians; Iterative polynomial fitting; ENHANCED LASER-DESORPTION; RAMAN-SPECTRA; SUBTRACTION; IONIZATION; REGRESSION;
D O I
10.1366/000370210792434350
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Baselines are often chosen by visual inspection of their effect on selected spectra. A more objective procedure for choosing baseline correction algorithms and their parameter values for use in statistical analysis is presented. When the goal of the baseline correction is spectra with a pleasing appearance, visual inspection can be a satisfactory approach. If the spectra are to be used in a statistical analysis, objectivity and reproducibility are essential for good prediction. Variations in baselines from dataset to dataset means we have no guarantee that the best-performing algorithm from one analysis will be the best when applied to a new dataset. This paper focuses on choosing baseline correction algorithms and optimizing their parameter values based on the performance of the quality measure from the given analysis. Results presented in this paper illustrate the potential benefits of the optimization and points out some of the possible pitfalls of baseline correction.
引用
收藏
页码:1007 / 1016
页数:10
相关论文
共 17 条
[1]   Raman spectra of biological samples: A study of preprocessing methods [J].
Afseth, Nils Kristian ;
Segtnan, Vegard Herman ;
Wold, Jens Petter .
APPLIED SPECTROSCOPY, 2006, 60 (12) :1358-1367
[2]  
[Anonymous], 1989, MULTIVARIATE CALIBRA
[3]   Exploring complex interactions in designed data using GEMANOVA. Color changes in fresh beef during storage [J].
Bro, R ;
Jakobsen, M .
JOURNAL OF CHEMOMETRICS, 2002, 16 (06) :294-304
[4]   Improved peak detection and quantification of mass spectrometry data acquired from surface-enhanced laser desorption and ionization by denoising spectra with the undecimated discrete wavelet transform [J].
Coombes, KR ;
Tsavachidis, S ;
Morris, JS ;
Baggerly, KA ;
Hung, MC ;
Kuerer, HM .
PROTEOMICS, 2005, 5 (16) :4107-4117
[5]   Quality control and peak finding for proteomics data collected from nipple aspirate fluid by surface-enhanced laser desorption and ionization [J].
Coombes, KR ;
Fritsche, HA ;
Clarke, C ;
Chen, JN ;
Baggerly, KA ;
Morris, JS ;
Xiao, LC ;
Hung, MC ;
Kuerer, HM .
CLINICAL CHEMISTRY, 2003, 49 (10) :1615-1623
[6]   ORTHONORMAL BASES OF COMPACTLY SUPPORTED WAVELETS [J].
DAUBECHIES, I .
COMMUNICATIONS ON PURE AND APPLIED MATHEMATICS, 1988, 41 (07) :909-996
[7]   Parametric time warping [J].
Eilers, PHC .
ANALYTICAL CHEMISTRY, 2004, 76 (02) :404-411
[8]  
FRIEDRICHS MS, 1995, J BIOMOL NMR, V5, P147, DOI 10.1007/BF00208805
[9]   Baseline correction by improved iterative polynomial fitting with automatic threshold [J].
Gan, Feng ;
Ruan, Guihua ;
Mo, Jinyuan .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2006, 82 (1-2) :59-65
[10]  
Hastie T., 2001, ELEMENTS STAT LEARNI