Effect of extraction vessel geometry and flow homogeneity on recoveries of polycyclic aromatic hydrocarbons in pressurised hot water extraction

被引:9
作者
Andersson, T [1 ]
Pihtsalmi, T [1 ]
Hartonen, K [1 ]
Hyötyläinen, T [1 ]
Riekkola, ML [1 ]
机构
[1] Univ Helsinki, Dept Chem, Analyt Chem Lab, FIN-00014 Helsinki, Finland
基金
芬兰科学院;
关键词
polycyclic aromatic hydrocarbons; pressurised hot water extraction; extraction vessel geometry; water flow direction; sediment packing;
D O I
10.1007/s00216-003-2078-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Extraction vessels of different length, internal diameter and volume were tested to evaluate the effect of vessel geometry on the recovery of polycyclic aromatic hydrocarbons (PAHs) from certified sediment by pressurised hot water extraction (PHWE). Pressurised hot water extractions were performed at 300 degreesC with both liquid water (pressure 250 kg cm(-2)) and steam (pressure 50 kg cm(-2)). In addition, the effects on the recoveries of sediment packing and water flow direction were examined in two vessels. The geometry of the vessel, the packing of the sediment and the flow direction of the water had only minor effect on the recoveries.
引用
收藏
页码:1081 / 1088
页数:8
相关论文
共 27 条
[1]   Stability of polycyclic aromatic hydrocarbons in pressurised hot water [J].
Andersson, T ;
Hartonen, K ;
Hyötyläinen, T ;
Riekkola, ML .
ANALYST, 2003, 128 (02) :150-155
[2]   Pressurised hot water extraction and thermal desorption of polycyclic aromatic hydrocarbons from sediment with use of a novel extraction vessel [J].
Andersson, T ;
Hartonen, K ;
Hyötyläinen, T ;
Riekkola, ML .
ANALYTICA CHIMICA ACTA, 2002, 466 (01) :93-100
[3]   Extraction of rosemary by superheated water [J].
Basile, A ;
Jiménez-Carmona, MM ;
Clifford, AA .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1998, 46 (12) :5205-5209
[4]   Continuous liquid-liquid extraction using modified subcritical water for the demetalisation of used industrial oils [J].
Fernández-Pérez, V ;
Jiménez-Carmona, MM ;
de Castro, MDL .
ANALYTICA CHIMICA ACTA, 2001, 433 (01) :47-52
[5]   THE DEPENDENCE OF SORBENT ANALYTE TYPE ON OBSERVED DIFFERENCES IN SUPERCRITICAL FLUID EXTRACTION EFFICIENCIES EMPLOYING EXTRACTION VESSELS OF DIFFERENT DIMENSIONS [J].
FURTON, KG ;
LIN, Q .
CHROMATOGRAPHIA, 1992, 34 (3-4) :185-187
[6]   Coupled subcritical water extraction with solid-phase microextraction for determining semivolatile organics in environmental solids [J].
Hageman, KJ ;
Mazeas, L ;
Grabanski, CB ;
Miller, DJ ;
Hawthorne, SB .
ANALYTICAL CHEMISTRY, 1996, 68 (22) :3892-3898
[7]  
Hartonen K, 2000, J MICROCOLUMN SEP, V12, P412, DOI 10.1002/1520-667X(2000)12:7<412::AID-MCS5>3.0.CO
[8]  
2-N
[9]   Extraction of polychlorinated biphenyls with water under subcritical conditions [J].
Hartonen, K ;
Inkala, K ;
Kangas, M ;
Riekkola, ML .
JOURNAL OF CHROMATOGRAPHY A, 1997, 785 (1-2) :219-226
[10]   Simple method for estimating polychlorinated biphenyl concentrations on soils and sediments using subcritical water extraction coupled with solid-phase microextraction [J].
Hawthorne, SB ;
Grabanski, CB ;
Hageman, KJ ;
Miller, DJ .
JOURNAL OF CHROMATOGRAPHY A, 1998, 814 (1-2) :151-160