Aptamer-based electrochemical biosensor for label-free voltammetric detection of thrombin and adenosine

被引:80
作者
Yan, Fangfang
Wang, Fang [1 ]
Chen, Zilin
机构
[1] Wuhan Univ, Key Lab Combinatorial Biosynth & Drug Discovery, Minist Educ, Wuhan 430071, Peoples R China
关键词
Aptamer; Electrochemical biosensor; Methylene blue; Thrombin; Adenosine; MOLECULAR RECOGNITION; GOLD NANOPARTICLES; DNA APTAMER; SENSING PLATFORM; AU NANOPARTICLES; CANCER-CELLS; APTASENSOR; SELECTION; PROBE; AMPLIFICATION;
D O I
10.1016/j.snb.2011.09.081
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A bifunctional aptamer-based electrochemical biosensor for label-free detection of thrombin and adenosine has been developed. It was based on the principle of switching structures of aptamers from DNA/DNA duplex to DNA/target complex upon target addition. Thrombin aptamer was firstly immobilized on gold electrode surface by self-assembly, and then it was hybridized with adenosine aptamer. Methylene blue (MB), as an electrochemical indicator, was abundantly adsorbed on the aptamers via specific interaction of MB with guanine base. In the presence of thrombin or adenosine, the aptamer part could bind with thrombin or adenosine instead of MB. The decreased peak current of MB was intimately related to the concentration of thrombin or adenosine. In present work, the assay was linear in the ranges from 6 to 60 nM for thrombin and from 10 to 1000 nM for adenosine. Detection limits were determined to be 3 nM for thrombin and 10 nM for adenosine, respectively. Moreover, bovine plasma albumin (BSA) and lysozyme, or uridine and guanosine, did not influence performance of the biosensor, indicating good selectivity of this sensor for thrombin or adenosine detection. Finally, this sensor was successfully applied to thrombin and adenosine analysis in human plasma samples. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:1380 / 1385
页数:6
相关论文
共 50 条
[1]   Electrochemical DNA aptamer-based biosensor for OTA detection, using superparamagnetic nanoparticles [J].
Barthelmebs, Lise ;
Hayat, Akhtar ;
Limiadi, Ambrosius Wis ;
Marty, Jean-Louis ;
Noguer, Thierry .
SENSORS AND ACTUATORS B-CHEMICAL, 2011, 156 (02) :932-937
[2]   Thrombin: Structure, biochemistry, measurement, and status in clinical medicine [J].
Becker, RC ;
Spencer, FA .
JOURNAL OF THROMBOSIS AND THROMBOLYSIS, 1998, 5 (03) :215-229
[3]   In vitro selection of DNA aptamers to anthrax spores with electrochemiluminescence detection [J].
Bruno, JG ;
Kiel, JL .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (05) :457-464
[4]   Detection of daunomycin using phosphatidylserine and aptamer co-immobilized on Au nanoparticles deposited conducting polymer [J].
Chandra, Pranjal ;
Noh, Hui-Bog ;
Won, Mi-Sook ;
Shim, Yoon-Bo .
BIOSENSORS & BIOELECTRONICS, 2011, 26 (11) :4442-4449
[5]   Inhibitory RNA ligand to reverse transcriptase from feline immunodeficiency virus [J].
Chen, H ;
McBroom, DG ;
Zhu, YQ ;
Gold, L ;
North, TW .
BIOCHEMISTRY, 1996, 35 (21) :6923-6930
[6]   Molecular recognition of small-cell lung cancer cells using aptamers [J].
Chen, Hui William ;
Medley, Colin D. ;
Sefah, Kwame ;
Shangguan, Dihua ;
Tang, Zhiwen ;
Meng, Ling ;
Smith, Josh E. ;
Tan, Weihong .
CHEMMEDCHEM, 2008, 3 (06) :991-1001
[7]   Aptamer-based biosensors for label-free voltammetric detection of lysozyme [J].
Cheng, Alan K. H. ;
Ge, Bixia ;
Yu, Hua-Zhong .
ANALYTICAL CHEMISTRY, 2007, 79 (14) :5158-5164
[8]   3 SMALL RIBOOLIGONUCLEOTIDES WITH SPECIFIC ARGININE SITES [J].
CONNELL, GJ ;
ILLANGESEKARE, M ;
YARUS, M .
BIOCHEMISTRY, 1993, 32 (21) :5497-5502
[9]   Adenosine level in exhaled breath increases during exercise-induced bronchoconstriction [J].
Csoma, Z ;
Huszár, É ;
Vizi, É ;
Vass, G ;
Szabó, Z ;
Herjavecz, I ;
Kollai, M ;
Horváth, I .
EUROPEAN RESPIRATORY JOURNAL, 2005, 25 (05) :873-878
[10]   Impedimetric Aptasensor with Femtomolar Sensitivity Based on the Enlargement of Surface-Charged Gold Nanoparticles [J].
Deng, Chunyan ;
Chen, Jinhua ;
Nie, Zhou ;
Wang, Mengdong ;
Chu, Xiaochen ;
Chen, Xiaoli ;
Xiao, Xilin ;
Lei, Chunyang ;
Yao, Shouzhuo .
ANALYTICAL CHEMISTRY, 2009, 81 (02) :739-745