Impedimetric Aptasensor with Femtomolar Sensitivity Based on the Enlargement of Surface-Charged Gold Nanoparticles

被引:147
作者
Deng, Chunyan [1 ]
Chen, Jinhua [1 ]
Nie, Zhou [1 ]
Wang, Mengdong [1 ]
Chu, Xiaochen [1 ]
Chen, Xiaoli [1 ]
Xiao, Xilin [1 ]
Lei, Chunyang [1 ]
Yao, Shouzhuo [1 ]
机构
[1] Hunan Univ, Coll Chem & Chem Engn, State Key Lab Chemo Biosensing & Chemometr, Changsha 410082, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
ROLLING CIRCLE AMPLIFICATION; IN-VITRO SELECTION; ELECTROCHEMICAL DETECTION; IMPEDANCE SPECTROSCOPY; INSOLUBLE PRODUCT; DNA; REAGENTLESS; PROTEINS; PRECIPITATION; BIOSENSOR;
D O I
10.1021/ac800958a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and ultrasensitive label-free electrochemical impedimetric aptasensor for thrombin based on the cascaded signal amplification was reported. The sandwich system of aptamer/thrombin/aptamer-functionalized Au nanoparticles (Apt-AuNPs) was fabricated as the sensing platform. The change of the interfacial feature of the electrode was characterized by electrochemical impedance analysis with the redox probe [Fe(CN)(6)](3-/4-). For improving detection sensitivity, the three-level cascaded impedimetric signal amplification was developed: (1) Apt-AuNPs as the first-level signal enhancer; (2) the steric-hindrance between the enlarged Apt-AuNPs as the second-level signal amplification; (3) the electrostatic-repulsion between sodium dodecylsulfate (SDS) stabilized Apt-AuNPs and the redox probe [Fe(CN)6]3-/4- as the third-level signal amplification. Enlargement of Apt-AuNPs integrated with negatively charged surfactant (SDS) capping could not only improve the detection sensitivity of the impedimetric aptasensor for thrombin but also present a simple and general signal-amplification model for impedimetric sensor. The aptasensor based on the enlargement of negatively charged Apt-AuNPs showed an increased response of the electron-transfer resistance to the increase of thrombin concentration through a wide detection range from 100 fM to 100 nM. The linear detection range was 0.05-35 nM, and thrombin was easily detectable to a concentration of 100 fM. The aptasensor also has good selectivity and reproducibility.
引用
收藏
页码:739 / 745
页数:7
相关论文
共 44 条
  • [1] Chronopotentiometry and Faradaic impedance spectroscopy as signal transduction methods for the biocatalytic precipitation of an insoluble product on electrode supports: routes for enzyme sensors, immunosensors and DNA sensors
    Alfonta, L
    Bardea, A
    Khersonsky, O
    Katz, E
    Willner, I
    [J]. BIOSENSORS & BIOELECTRONICS, 2001, 16 (9-12) : 675 - 687
  • [2] BELLE JTL, 2007, ANAL CHEM, V79, P6959
  • [3] Label-free protein recognition using an aptamer-based impedance measurement assay
    Cai, H
    Lee, TMH
    Hsing, IM
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2006, 114 (01) : 433 - 437
  • [4] Aptamer-based biosensors for label-free voltammetric detection of lysozyme
    Cheng, Alan K. H.
    Ge, Bixia
    Yu, Hua-Zhong
    [J]. ANALYTICAL CHEMISTRY, 2007, 79 (14) : 5158 - 5164
  • [5] INVITRO SELECTION OF RNA MOLECULES THAT BIND SPECIFIC LIGANDS
    ELLINGTON, AD
    SZOSTAK, JW
    [J]. NATURE, 1990, 346 (6287) : 818 - 822
  • [6] BLOCKING ORIENTED MONOLAYERS OF ALKYL MERCAPTANS ON GOLD ELECTRODES
    FINKLEA, HO
    AVERY, S
    LYNCH, M
    FURTSCH, T
    [J]. LANGMUIR, 1987, 3 (03) : 409 - 413
  • [7] Selection and analytical applications of aptamers
    Hamula, Camille L. A.
    Guthrie, Jeffrey W.
    Zhang, Hongquan
    Li, Xing-Fang
    Le, X. Chris
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2006, 25 (07) : 681 - 691
  • [8] Quantum-dot/aptamer-based ultrasensitive multi-analyte electrochemical biosensor
    Hansen, JA
    Wang, J
    Kawde, AN
    Xiang, Y
    Gothelf, KV
    Collins, G
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (07) : 2228 - 2229
  • [9] Ultrasensitive electrochemical detection of proteins by amplification of aptamer-nanoparticle bio bar codes
    He, Pingli
    Shen, Li
    Cao, Yunhe
    Lia, Defa
    [J]. ANALYTICAL CHEMISTRY, 2007, 79 (21) : 8024 - 8029
  • [10] Aptamer-modified gold nanoparticles for colorimetric determination of platelet-derived growth factors and their receptors
    Huang, CC
    Huang, YF
    Cao, ZH
    Tan, WH
    Chang, HT
    [J]. ANALYTICAL CHEMISTRY, 2005, 77 (17) : 5735 - 5741