Microfabricated bioreactor chips for immobilised enzyme assays

被引:17
作者
Banu, S [1 ]
Greenway, GM [1 ]
McCreedy, T [1 ]
Shaddick, R [1 ]
机构
[1] Univ Hull, Dept Chem, Kingston Upon Hull HU6 7RX, N Humberside, England
关键词
bioreactor; controlled pore glass; microfabricated device; xanthine oxidase; alkaline phosphatase;
D O I
10.1016/S0003-2670(03)00503-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A microfabricated device is reported that has been designed to permit the in situ packing of a section of channel with enzyme immobilised onto controlled pore glass (CPG). It is fabricated from glass and polydimethylsiloxane and to prevent dead volumes, has dedicated channels for packing the reactor. The device has the advantage of being simple in design, the flow through enzyme reactor channel being simply a widened section of the analyte channel. The system is suitable for both hydrodynamic and electro-osmotic pumping, and is designed such that when the packing is exhausted it can be repacked. Controlled pore glass provides a reproducible none swelling, high porosity medium onto which the enzyme could be immobilised. The large particle size meant that it was vital to optimise the immobilisation procedure in order to achieve acceptable enzyme activity. The microfabricated device was developed with two enzymes of different molecular masses; alkaline phosphatase and xanthine oxidase. The pore size of the CPG was found to be very important for xanthine oxidase, where the 697 Angstrom pore size (120-200 mesh) CPG was found to give the highest activity (18-20% activity retained after immobilisation). The microfabricated device was used for the assay of p-nitrophenyl phosphate and hypoxanthine with spectrophotometric detection at 405 and 470 nm, respectively. The limits of detection were 5 and 8 muM, respectively. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:149 / 157
页数:9
相关论文
共 22 条
  • [1] On-line gas chromatographic monitoring of catalyst processes in a microfabricated chemical reactor
    Al-Gailani, BRM
    McCreedy, T
    [J]. CHEMICAL COMMUNICATIONS, 2003, (01) : 120 - 121
  • [2] Immobilization of xanthine oxidase and its use in the quantitation of hypoxanthine in fish muscle tissue extracts using a flow injection method
    Balladin, DA
    Narinesingh, D
    Stoute, VA
    Ngo, TT
    [J]. APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 1997, 62 (2-3) : 317 - 328
  • [3] Bickerstaff G. F., 1997, IMMOBILISATION ENZYM
  • [4] An integrated microfluidic biochemical detection system for protein analysis with magnetic bead-based sampling capabilities
    Choi, JW
    Oh, KW
    Thomas, JH
    Heineman, WR
    Halsall, HB
    Nevin, JH
    Helmicki, AJ
    Henderson, HT
    Ahn, CH
    [J]. LAB ON A CHIP, 2002, 2 (01) : 27 - 30
  • [5] FLOW-INJECTION DETERMINATION OF PENICILLINS USING IMMOBILIZED PENICILLINASE IN A SINGLE BEAD STRING REACTOR
    GNANASEKARAN, R
    MOTTOLA, HA
    [J]. ANALYTICAL CHEMISTRY, 1985, 57 (06) : 1005 - 1009
  • [6] Microfluidic assays of acetylcholinesterase inhibitors
    Hadd, AG
    Jacobson, SC
    Ramsey, JM
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (22) : 5206 - 5212
  • [7] Simultaneous detection of uric acid and glucose on a dual-enzyme chip using scanning electrochemical microscopy/scanning chemiluminescence microscopy
    Kasai, S
    Hirano, Y
    Motochi, N
    Shiku, H
    Nishizawa, M
    Matsue, T
    [J]. ANALYTICA CHIMICA ACTA, 2002, 458 (02) : 263 - 270
  • [8] LAM S, 1994, ANAL APPL IMMOBILISE, P133
  • [9] LAM S, 1994, ANAL APPL IMMOBILISE, P12
  • [10] Design and characterization of immobilized enzymes in microfluidic systems
    Mao, HB
    Yang, TL
    Cremer, PS
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (02) : 379 - 385