Continuous on-line determination of methyl tert-butyl ether in water samples using ion mobility spectrometry

被引:35
作者
Borsdorf, H [1 ]
Rämmler, A [1 ]
机构
[1] UFZ Helmholtz Ctr Environm Res, Dept Analyt Chem, Ctr Environm Res Leipzig Halle, D-04301 Leipzig, Germany
关键词
methyl tent-butyl ether; water samples; ion mobility spectrometry; membrane inlet;
D O I
10.1016/j.chroma.2004.12.041
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A rapid analytical procedure for the on-line determination of methyl tent-butyl ether (MTBE) in water samples was developed. A new membrane extraction unit was used to extract the MTBE from water samples. The concentration of MTBE was determined using ion mobility spectrometry with Ni-63 ionization and corona discharge ionization without chromatographic separation. Both ionization methods permit the sensitive determination of MTBE. A detection limit of 100 mu g/L was established for the on-line procedure. Neither the inorganic compounds, humic substances nor gasoline were found to exert a significant influence on the peak intensity of the MTBE. The screening procedure can be used for concentrations of monoaromatic compounds (benzene, toluene, xylene) up to 600 mu g/L. No sample preparation is required and the analysis results are available within 5 min. In order to determine concentrations between 10 mu g/L and 100 mu g/L, a discontinuous procedure was developed on the basis of the same experimental set-up. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:45 / 54
页数:10
相关论文
共 29 条
[1]   Sensitive method for determination of methyl tert-butyl ether (MTBE) in water by use of headspace-SPME/GC-MS [J].
Achten, C ;
Kolb, A ;
Püttmann, W .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 371 (04) :519-525
[2]  
ADLER J, 1998, RECENT DEV ION MOBIL, P110
[3]   Water solubilization of ethanol and BTEX from gasoline: on-line monitoring by membrane introduction mass spectrometry [J].
Alberici, RM ;
Zampronio, CG ;
Poppi, RJ ;
Eberlin, MN .
ANALYST, 2002, 127 (02) :230-234
[4]   Detection of the gasoline components methyl tert-butyl ether, benzene, toluene, and m-xylene using ion mobility spectrometers with a radioactive and UV ionization source [J].
Baumbach, JI ;
Sielemann, S ;
Xie, ZY ;
Schmidt, H .
ANALYTICAL CHEMISTRY, 2003, 75 (06) :1483-1490
[5]   Ion mobility spectrometry: Arriving on site and moving beyond a low profile [J].
Baumbach, JI ;
Eiceman, GA .
APPLIED SPECTROSCOPY, 1999, 53 (09) :338A-355A
[6]   Atmospheric pressure ionization and gas phase ion mobility studies of isomeric dihalogenated benzenes using different ionization techniques [J].
Borsdorf, H ;
Nazarov, EG ;
Eiceman, GA .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2004, 232 (02) :117-126
[7]   Atmospheric pressure chemical ionization studies of non-polar isomeric hydrocarbons using ion mobility spectrometry and mass spectrometry with different ionization techniques [J].
Borsdorf, H ;
Nazarov, EG ;
Eiceman, GA .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2002, 13 (09) :1078-1087
[8]   Rapid on-site determination of chlorobenzene in water samples using ion mobility spectrometry [J].
Borsdorf, H ;
Rämmler, A ;
Schulze, D ;
Boadu, KO ;
Feist, B ;
Weiss, H .
ANALYTICA CHIMICA ACTA, 2001, 440 (01) :63-70
[9]  
BORSDORF H, 1999, INT J ION MOBILITY S, V2, P9
[10]   Determination of methyl tert-butyl ether (MTBE) in aqueous samples by purge and trap-gas chromatography-flame ionization detector [J].
Cheng, W ;
Liu, JM ;
Jiang, GB ;
Yao, ZW .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2003, 83 (04) :285-293