Long-term Doppler echocardiographic results of aortic or mitral valve replacement with biocor porcine bioprosthesis

被引:11
作者
Mykén, PSU
Berggren, HE
Larsson, S
Roberts, B
Wallentin, I
Caidahl, K [1 ]
机构
[1] Sahlgrens Univ Hosp, Dept Clin Physiol, S-41345 Gothenburg, Sweden
[2] Sahlgrens Univ Hosp, Dept Thorac & Cardiovasc Surg, S-41345 Gothenburg, Sweden
关键词
D O I
10.1016/S0022-5223(98)70166-7
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Objectives: Our objectives were to evaluate the long-term bioprosthetic and cardiac functional outcome after insertion (over a 10-year period) of a new-generation porcine zero pressure-fixed Biocor bioprosthesis, as well as to determine the echocardiographic accuracy for selection of patients requiring reoperation. The long-term systematic Doppler echocardiographic assessment after valve replacement with this bioprosthesis is lacking. Methods: Between January 1983 and January 1993, we inserted 756 Biocor prostheses in the aortic (619) or mitral (137) positions. All 51 patients who had a reoperation during the follow-up time were evaluated echocardiographically before reoperation. Additionally, 263 of 446 patients (59%) with aortic bioprostheses and 42 of 74 patients (57%) with mitral bioprostheses who were alive in January 1993 had long-term echocardiographic follow-up, Results: Group A: Normally functioning bioprostheses were found in the aortic position in 242 of 263 patients and in the mitral position in 33 of 42 patients, Group B: Thirty patients had abnormal bioprosthetic function. Eleven patients had regurgitation, 3 had a combined lesion, and signs of calcification appeared in 16 patients with aortic valves, all with a peak gradient of above 60 mm Hg, Group C: Patients who had a reoperation (41 aortic and 10 mitral) within the follow-up period were followed up echocardiographically from the detection of a possible valve dysfunction until reoperation, and the findings accorded well with those at operation in 49 of 51 patients, Conclusions: These findings suggest that, during a long-term follow-up, most bioprostheses function normally, facilitating improved heart function. Abnormalities in a bioprosthesis usually develop gradually, enabling their detection by Doppler echocardiographic evaluations performed regularly or in case of any symptomatic deterioration.
引用
收藏
页码:599 / 608
页数:10
相关论文
共 28 条
[1]
DOPPLER AND ECHOCARDIOGRAPHIC FEATURES OF NORMAL AND DYSFUNCTIONING BIOPROSTHETIC VALVES [J].
ALAM, M ;
ROSMAN, HS ;
LAKIER, JB ;
KEMP, S ;
KHAJA, F ;
HAUTAMAKI, K ;
MAGILLIGAN, DJ ;
STEIN, PD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 10 (04) :851-858
[2]
TRANSESOPHAGEAL ECHOCARDIOGRAPHIC FEATURES OF NORMAL AND DYSFUNCTIONING BIOPROSTHETIC VALVES [J].
ALAM, M ;
SERWIN, JB ;
ROSMAN, HS ;
POLANCO, GA ;
SUN, I ;
SILVERMAN, NA .
AMERICAN HEART JOURNAL, 1991, 121 (04) :1149-1155
[3]
Barratt-Boyes B G, 1993, J Heart Valve Dis, V2, P604
[4]
HANCOCK-II PORCINE BIOPROSTHESIS - EXCELLENT DURABILITY AT INTERMEDIATE-TERM FOLLOW-UP [J].
BORTOLOTTI, U ;
MILANO, A ;
MAZZARO, E ;
THIENE, G ;
TALENTI, E ;
CASAROTTO, D .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (03) :676-682
[5]
BURDON TA, 1992, J THORAC CARDIOV SUR, V103, P238
[6]
CAIDAHL K, 1988, BRIT HEART J, V59, P329
[7]
PATHOLOGICAL AND ANGIOGRAPHIC CORRELATIONS OF TRANSESOPHAGEAL ECHOCARDIOGRAPHY IN PROSTHETIC HEART-VALVE DYSFUNCTION [J].
CHAUDHRY, FA ;
HERRERA, C ;
DEFRINO, PF ;
MEHLMAN, DJ ;
ZABALGOITIA, M .
AMERICAN HEART JOURNAL, 1991, 122 (04) :1057-1064
[8]
15-YEAR EXPERIENCE WITH 1678 HANCOCK PORCINE BIOPROSTHETIC HEART-VALVE REPLACEMENTS [J].
COHN, LH ;
COLLINS, JJ ;
DISESA, VJ ;
COUPER, GS ;
PEIGH, PS ;
KOWALKER, W ;
ALLRED, E .
ANNALS OF SURGERY, 1989, 210 (04) :435-443
[9]
EVALUATION OF NORMAL PROSTHETIC VALVE FUNCTION BY DOPPLER ECHOCARDIOGRAPHY [J].
COOPER, DM ;
STEWART, WJ ;
SCHIAVONE, WA ;
LOMBARDO, HP ;
LYTLE, BW ;
LOOP, FD ;
SALCEDO, EE .
AMERICAN HEART JOURNAL, 1987, 114 (03) :576-582
[10]
COMPARISON OF TRANSTHORACIC AND TRANSESOPHAGEAL ECHOCARDIOGRAPHY FOR DETECTION OF ABNORMALITIES OF PROSTHETIC AND BIOPROSTHETIC VALVES IN THE MITRAL AND AORTIC POSITIONS [J].
DANIEL, WG ;
MUGGE, A ;
GROTE, J ;
HAUSMANN, D ;
NIKUTTA, P ;
LAAS, J ;
LICHTLEN, PR ;
MARTIN, RP .
AMERICAN JOURNAL OF CARDIOLOGY, 1993, 71 (02) :210-215