Enzymatically synthesized polyaniline layer for extension of linear detection region of amperometric glucose biosensor

被引:87
作者
Kausaite-Minkstimiene, Asta [1 ]
Mazeiko, Viktor [1 ]
Ramanaviciene, Almira [1 ,2 ]
Ramanavicius, Arunas [1 ,3 ]
机构
[1] Vilnius Univ, NanoTechnas Ctr Nanotechnol & Mat Sci, Fac Chem, LT-03225 Vilnius, Lithuania
[2] State Res Inst Ctr Innovat Med, Lab Immunotechnol, LT-01102 Vilnius, Lithuania
[3] State Res Inst Ctr Phys & Technol Sci, Inst Chem, LT-01108 Vilnius, Lithuania
关键词
Amperometric glucose biosensor; Immobilized glucose oxidase; Biofuel cells; Conducting polymers; Polyaniline; CONDUCTING POLYMER; OXIDASE; IMMOBILIZATION; FILMS; NANOPARTICLES; ELECTRODE; ENZYMES; GOD;
D O I
10.1016/j.bios.2010.06.023
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In this article a new method for fabrication of enzymatic electrodes suitable for design of amperometric glucose biosensor and/or anode of biofuel cell powered by glucose is presented. Glucose oxidase (GOx) E.C. 1.1.3.4. from Penicillium vitale was immobilized on the carbon rod electrode by cross-linking it with glutaraldehyde (GOx-electrode). Catalytic activity of immobilized GOx was exploited for polymerisation of aniline by taking a high concentration of hydrogen peroxide produced during the catalytic action of immobilized GOx and locally lowered pH due to the formation of gluconic acid; it created optimal conditions for the polymerisation of aniline. The GOx layer was self-encapsulated within formed polyaniline (PANI) matrix (GOx/PANI-electrode). Properties of the GOx/PANI-electrode have been studied and results were compared with GOx-electrode. The results show that the upper detection limit of glucose using GOx-electrode was dramatically changed by the formation of PAN! layer. An increase in the upper detection limit, optimal pH region for operation and stability of GOx based electrode modified by PANI was detected when comparing that of an unmodified GOx-electrode. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:790 / 797
页数:8
相关论文
共 58 条
[1]   Biomolecular immobilization on conducting polymers for biosensing applications [J].
Ahuja, Tarushee ;
Mir, Irfan Ahmad ;
Kumar, Devendra ;
Rajesh .
BIOMATERIALS, 2007, 28 (05) :791-805
[2]   Microtubular conductometric biosensor for ethanol detection [J].
Ajay, A. K. ;
Srivastava, Divesh N. .
BIOSENSORS & BIOELECTRONICS, 2007, 23 (02) :281-284
[3]   Development of a potentiometric catechol biosensor by entrapment of tyrosinase within polypyrrole film [J].
Ameer, Qaisar ;
Adeloju, Samuel B. .
SENSORS AND ACTUATORS B-CHEMICAL, 2009, 140 (01) :5-11
[4]   The influence of the enzyme membrane thickness on the response of amperometric biosensors [J].
Baronas, R ;
Ivanauskas, F ;
Kulys, J .
SENSORS, 2003, 3 (07) :248-262
[5]  
BARONAS R, 2010, MATH MODELING BIOSEN, P60
[6]   POLYANILINE - PROTONIC ACID DOPING OF THE EMERALDINE FORM TO THE METALLIC REGIME [J].
CHIANG, JC ;
MACDIARMID, AG .
SYNTHETIC METALS, 1986, 13 (1-3) :193-205
[7]   ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY [J].
CLARK, LC ;
LYONS, C .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) :29-&
[8]   Biosensors based on electropolymerized films: new trends [J].
Cosnier, S .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (03) :507-520
[9]   Comparative study of polyaniline cast films prepared from enzymatically and chemically synthesized polyaniline [J].
Cruz-Silva, R ;
Romero-García, J ;
Angulo-Sánchez, JL ;
Flores-Loyola, E ;
Farías, MH ;
Castillón, FF ;
Díaz, JA .
POLYMER, 2004, 45 (14) :4711-4717
[10]  
DAVIS F, 2007, BIOMEDICAL POLYM, P236