Biomolecular immobilization on conducting polymers for biosensing applications

被引:368
作者
Ahuja, Tarushee
Mir, Irfan Ahmad
Kumar, Devendra
Rajesh
机构
[1] CSIR, Intellectual Property Management Div, New Delhi 110067, India
[2] Univ Delhi, Delhi Coll Engn, Dept Appl Chem, Delhi 110042, India
关键词
conducting polymers; biosensors; electrochemical polymerization; physical adsorption; covalent immobilization; electrochemical immobilization; POLYPYRROLE BIENZYME ELECTRODES; HYDROGEN-PEROXIDE BIOSENSOR; GLUCOSE-OXIDASE; ENZYME ELECTRODE; HORSERADISH-PEROXIDASE; AMPEROMETRIC BIOSENSOR; CHOLESTEROL OXIDASE; ELECTROCHEMICAL IMMOBILIZATION; COVALENT ELECTROPOLYMERIZATION; POLYPHENOL OXIDASE;
D O I
10.1016/j.biomaterials.2006.09.046
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A detail study on different aspects of biomolecule immobilization techniques on conducting polymers (CP) for applications in biosensors is described. Comparative studies are conducted in between the different mode of biomolecule immobilization techniques, viz. physical, covalent and electrochemical immobilization onto the conducting polymer films for the fabrication of electrochemical biosensors for clinical, food and environmental monitoring applications. This review focuses on the current status of biomolecule immobilization techniques on CP and their applications in the development of amperometric biosensors. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:791 / 805
页数:15
相关论文
共 223 条
  • [1] Conducting polymers and the bioanalytical sciences: New tools for biomolecular communications - A review
    Adeloju, SB
    Wallace, GG
    [J]. ANALYST, 1996, 121 (06) : 699 - 703
  • [2] Electroimmobilisation of sulphite oxidase into a polypyrrole film and its utilisation for flow amperometric detection of sulphite
    Adeloju, SB
    Barisci, JN
    Wallace, GG
    [J]. ANALYTICA CHIMICA ACTA, 1996, 332 (2-3) : 145 - 153
  • [3] Polymers in sensor applications
    Adhikari, B
    Majumdar, S
    [J]. PROGRESS IN POLYMER SCIENCE, 2004, 29 (07) : 699 - 766
  • [4] AIZAWA M, 1985, P 51 ANN M JAP CHEM, P6
  • [5] Enzyme inhibition-based biosensors for food safety and environmental monitoring
    Amine, A
    Mohammadi, H
    Bourais, I
    Palleschi, G
    [J]. BIOSENSORS & BIOELECTRONICS, 2006, 21 (08) : 1405 - 1423
  • [6] Electrochemical characteristics of D-amino acid oxidase Immobilized in a conductive redox polymer
    Arai, G
    Noma, T
    Hayashi, M
    Yasumori, I
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1998, 452 (01): : 43 - 48
  • [7] Metal-dispersed conducting polymer-coated electrode used for oxidase-based biosensors
    Arjsiriwat, S
    Tanticharoen, M
    Kirtikara, K
    Aoki, K
    Somasundrum, M
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2000, 2 (06) : 441 - 444
  • [8] Recent developments in bio-molecular electronics techniques for food pathogens
    Arora, Kavita
    Chand, Subhash
    Malhotra, B. D.
    [J]. ANALYTICA CHIMICA ACTA, 2006, 568 (1-2) : 259 - 274
  • [9] Novel conducting polymer electrolyte biosensor based on poly(1-vinyl imidazole) and poly(acrylic acid) networks
    Arslan, A
    Kiralp, S
    Toppare, L
    Bozkurt, A
    [J]. LANGMUIR, 2006, 22 (06) : 2912 - 2915
  • [10] Immobilization of tyrosinase in polysiloxane/polypyrrole copolymer matrices
    Arslan, A
    Kiralp, S
    Toppare, L
    Yagci, Y
    [J]. INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2005, 35 (3-4) : 163 - 167