Enzymatically synthesized polyaniline layer for extension of linear detection region of amperometric glucose biosensor

被引:87
作者
Kausaite-Minkstimiene, Asta [1 ]
Mazeiko, Viktor [1 ]
Ramanaviciene, Almira [1 ,2 ]
Ramanavicius, Arunas [1 ,3 ]
机构
[1] Vilnius Univ, NanoTechnas Ctr Nanotechnol & Mat Sci, Fac Chem, LT-03225 Vilnius, Lithuania
[2] State Res Inst Ctr Innovat Med, Lab Immunotechnol, LT-01102 Vilnius, Lithuania
[3] State Res Inst Ctr Phys & Technol Sci, Inst Chem, LT-01108 Vilnius, Lithuania
关键词
Amperometric glucose biosensor; Immobilized glucose oxidase; Biofuel cells; Conducting polymers; Polyaniline; CONDUCTING POLYMER; OXIDASE; IMMOBILIZATION; FILMS; NANOPARTICLES; ELECTRODE; ENZYMES; GOD;
D O I
10.1016/j.bios.2010.06.023
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In this article a new method for fabrication of enzymatic electrodes suitable for design of amperometric glucose biosensor and/or anode of biofuel cell powered by glucose is presented. Glucose oxidase (GOx) E.C. 1.1.3.4. from Penicillium vitale was immobilized on the carbon rod electrode by cross-linking it with glutaraldehyde (GOx-electrode). Catalytic activity of immobilized GOx was exploited for polymerisation of aniline by taking a high concentration of hydrogen peroxide produced during the catalytic action of immobilized GOx and locally lowered pH due to the formation of gluconic acid; it created optimal conditions for the polymerisation of aniline. The GOx layer was self-encapsulated within formed polyaniline (PANI) matrix (GOx/PANI-electrode). Properties of the GOx/PANI-electrode have been studied and results were compared with GOx-electrode. The results show that the upper detection limit of glucose using GOx-electrode was dramatically changed by the formation of PAN! layer. An increase in the upper detection limit, optimal pH region for operation and stability of GOx based electrode modified by PANI was detected when comparing that of an unmodified GOx-electrode. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:790 / 797
页数:8
相关论文
共 58 条
[41]   Biocompatibility of polypyrrole particles: an in-vivo study in mice [J].
Ramanaviciene, Almira ;
Kausaite, Asta ;
Tautkus, Stasys ;
Ramanavicius, Arunas .
JOURNAL OF PHARMACY AND PHARMACOLOGY, 2007, 59 (02) :311-315
[42]   Amperometric biosensor for the determination of creatine [J].
Ramanavicius, A. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 387 (05) :1899-1906
[43]   Electrochemical sensors based on conducting polymer- polypyrrole [J].
Ramanavicius, A. ;
Ramanaviciene, A. ;
Malinauskas, A. .
ELECTROCHIMICA ACTA, 2006, 51 (27) :6025-6037
[44]   Polypyrrole-coated glucose oxidase nanoparticles for biosensor design [J].
Ramanavicius, A ;
Kausaitè, A ;
Ramanavicienè, A .
SENSORS AND ACTUATORS B-CHEMICAL, 2005, 111 :532-539
[45]  
Ramanavicius A, 2004, NATO SCI SER II-MATH, V180, P93
[46]   Hemoproteins in Design of Biofuel Cells [J].
Ramanavicius, A. ;
Ramanaviciene, A. .
FUEL CELLS, 2009, 9 (01) :25-36
[47]   Self-encapsulation of oxidases as a basic approach to tune the upper detection limit of amperometric biosensors [J].
Ramanavicius, Arunas ;
Kausaite, Asta ;
Ramanaviciene, Almira .
ANALYST, 2008, 133 (08) :1083-1089
[48]   MULTIPLE INHIBITION ANALYSIS OF ASPERGILLUS NIGER GLUCOSE OXIDASE BY D-GLUCAL AND HALIDE IONS [J].
ROGERS, MJ ;
BRANDT, KG .
BIOCHEMISTRY, 1971, 10 (25) :4636-&
[49]   Modeling and characterization of polyelectrolyte complex of polyaniline and sulfonated polystyrene produced by palm tree peroxidase [J].
Sakharov, IY ;
Ouporov, IV ;
Vorobiev, AK ;
Roig, MG ;
Pletjushkina, OY .
SYNTHETIC METALS, 2004, 142 (1-3) :127-135
[50]   Electrical contacting of glucose oxidase by DNA-templated polyaniline wires on surfaces [J].
Shi, LX ;
Xiao, Y ;
Willner, I .
ELECTROCHEMISTRY COMMUNICATIONS, 2004, 6 (10) :1057-1060