Diamond Penetrating Electrode Array For Epi-Retinal Prosthesis

被引:15
作者
Ganesan, K. [1 ,5 ]
Stacey, A. [1 ,5 ]
Meffin, H. [2 ,5 ]
Lichter, S. [1 ,4 ,5 ]
Greferath, U. [3 ,5 ]
Fletcher, E. L. [3 ,5 ]
Prawer, S. [1 ,5 ]
机构
[1] Univ Melbourne, Sch Phys, Parkville, Vic 3010, Australia
[2] NICTA, Victoria Res Lab, Parkville, Vic, Australia
[3] Univ Melbourne, Dept Anatomy & Cell Biolog, Parkville, Vic, Australia
[4] Univ Melbourne, Dept Chem & Biomol Engn, Parkville, Vic, Australia
[5] Bionic Vision Australia, Melbourne, Vic 3002, Australia
来源
2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC) | 2010年
关键词
D O I
10.1109/IEMBS.2010.5626003
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents progress in the characterization and application of diamond penetrating electrode arrays for Epi-Retinal Prostheses. Electrical stimulation of degenerate retina has already been shown to restore partial vision for some blind patients, albeit at low spatial resolution. Higher resolution may be achievable by building arrays with electrodes that have greater areal density and closer proximity to target neurons. However, high standards of biocompatibility and hermeticity must be maintained, limiting the range of available materials of manufacture. Here, the design and histology of high density electrode arrays(similar to 100 electrodes/mm(2)) made from polycrystalline diamond and implanted into rat retinae are discussed. Results from initial steps in this process are reported.
引用
收藏
页码:6757 / 6760
页数:4
相关论文
共 14 条
[1]   Chemical vapour deposition synthetic diamond: materials, technology and applications [J].
Balmer, R. S. ;
Brandon, J. R. ;
Clewes, S. L. ;
Dhillon, H. K. ;
Dodson, J. M. ;
Friel, I. ;
Inglis, P. N. ;
Madgwick, T. D. ;
Markham, M. L. ;
Mollart, T. P. ;
Perkins, N. ;
Scarsbrook, G. A. ;
Twitchen, D. J. ;
Whitehead, A. J. ;
Wilman, J. J. ;
Woollard, S. M. .
JOURNAL OF PHYSICS-CONDENSED MATTER, 2009, 21 (36)
[2]  
Horsager A., 2008, Invest Ophthalmol Vis Sci
[3]  
HUMAYUN M, 2009, INVEST OPHTHALMOL VI
[4]   Pattern electrical stimulation of the human retina [J].
Humayun, MS ;
de Juan, E ;
Weiland, JD ;
Dagnelie, G ;
Katona, S ;
Greenberg, R ;
Suzuki, S .
VISION RESEARCH, 1999, 39 (15) :2569-2576
[5]   Visual perception in a blind subject with a chronic microelectronic retinal prosthesis [J].
Humayun, MS ;
Weiland, JD ;
Fujii, GY ;
Greenberg, R ;
Williamson, R ;
Little, J ;
Mech, B ;
Cimmarusti, V ;
Van Boemel, G ;
Dagnelie, G ;
de Juan, E .
VISION RESEARCH, 2003, 43 (24) :2573-2581
[6]   A GLASS SILICON COMPOSITE INTRACORTICAL ELECTRODE ARRAY [J].
JONES, KE ;
CAMPBELL, PK ;
NORMANN, RA .
ANNALS OF BIOMEDICAL ENGINEERING, 1992, 20 (04) :423-437
[7]   Morphometric analysis of the macula in eyes with geographic atrophy due to age-related macular degeneration [J].
Kim, SY ;
Sadda, S ;
Humayun, MS ;
De Juan, E ;
Melia, BM ;
Green, WR .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2002, 22 (04) :464-470
[8]   Retinal Prosthesis Phosphene Shape Analysis [J].
Nanduri, D. ;
Humayun, M. S. ;
Greenberg, R. J. ;
McMahon, M. J. ;
Weiland, J. D. .
2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, :1785-+
[9]   Wireless technologies for closed-loop retinal prostheses [J].
Ng, David C. ;
Bai, Shun ;
Yang, Jiawei ;
Tran, Nhan ;
Skafidas, Efstratios .
JOURNAL OF NEURAL ENGINEERING, 2009, 6 (06)
[10]   Raman spectroscopy of diamond and doped diamond [J].
Prawer, S ;
Nemanich, RJ .
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2004, 362 (1824) :2537-2565