Design and performance of a data acquisition system for VUB-PET

被引:6
作者
Bruyndonckx, P [1 ]
Wang, YG
Tavernier, S
Carnochan, P
机构
[1] Free Univ Brussels, InterUniv Inst High Energies, B-1050 Brussels, Belgium
[2] Inst Sci & Technol China, Dept Modern Phys, Hefei 230027, Anhui, Peoples R China
[3] Inst Canc Res, Dept Phys, Sutton SM2 5PT, Surrey, England
[4] Royal Marsden NHS Trust, Sutton SM2 5PT, Surrey, England
关键词
data acquisition; positron emission tomography (PET);
D O I
10.1109/23.907579
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A flexible and high-speed VME-based data acquisition system (DAQ) has been designed to process data from the University of Brussels (VUB) small-animal positron emission tomography (PET) system. The core tasks of the system are performed by two custom VME modules: a trigger module and a Fast Readout module (FRO), Following the detection of a valid coincidence event by the trigger unit, the raw data from all analog-to-digital converter channels involved are read out simultaneously via a FRO. An onboard digital signal processor (DSP) processor checks and calibrates these data. To increase the transfer throughput of the list mode data to a SUN Ultra Spare 1 workstation, the DSP processor compresses the data format to a 6-byte data packet per event. The maximum average sustained acquisition rate of the system is 200 000 counts per second (cps), while peak rates up to 2 Mcps can be handled. The DAQ also provides online measurement of the random event rate, the single event rate and event losses due to electronic dead time.
引用
收藏
页码:150 / 156
页数:7
相关论文
共 11 条
[1]   Three-dimensional performance of a small-diameter positron emission tomograph [J].
Bloomfield, PM ;
Myers, R ;
Hume, SP ;
Spinks, TJ ;
Lammertsma, AA ;
Jones, T .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (02) :389-400
[2]   Design and physical characteristics of a small animal PET using BaF2 crystals and a photosensitive wire chamber [J].
Bruyndonckx, P ;
Liu, X ;
Rajeswaran, S ;
Smolik, W ;
Tavernier, S ;
Zhang, SP .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 382 (03) :589-600
[3]  
BRUYNDONCKX P, 1997, P IEEE NUCL SCI S
[4]  
Chatziioannou AF, 1999, J NUCL MED, V40, P1164
[5]   YAP-PET:: first results of a small animal Positron Emission Tomograph based on YAP:Ce finger crystals [J].
Del Guerra, A ;
Di Domenico, G ;
Scandola, M ;
Zavattini, G .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (06) :3105-3108
[6]   Imaging adenoviral-directed reporter gene expression in living animals with positron emission tomography [J].
Gambhir, SS ;
Barrio, JR ;
Phelps, ME ;
Iyer, M ;
Namavari, M ;
Satyamurthy, N ;
Wu, L ;
Green, LA ;
Bauer, E ;
MacLaren, DC ;
Nguyen, K ;
Berk, AJ ;
Cherry, SR ;
Herschman, HR .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1999, 96 (05) :2333-2338
[7]  
KNOLL GF, 1979, RAD DETECTION MEASUR, P120
[8]  
Lapointe D, 1999, J NUCL MED, V40, P876
[9]   Studies with a prototype high resolution PET scanner based on LSO-APD modules [J].
Pichler, B ;
Boning, G ;
Lorenz, E ;
Mirzoyan, R ;
Pimpl, W ;
Schwaiger, M ;
Ziegler, SI .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) :1298-1302
[10]   Evaluation of the TierPET system [J].
Weber, S ;
Herzog, H ;
Cremer, M ;
Engels, R ;
Hamacher, K ;
Kehren, F ;
Muehlensiepen, H ;
Ploux, L ;
Reinartz, R ;
Reinhart, P ;
Rongen, F ;
Sonnenberg, F ;
Coenen, HH ;
Halling, H .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (04) :1177-1183