High-throughput electrophysiology: an emerging paradigm for ion-channel screening and physiology

被引:368
作者
Dunlop, John [1 ]
Bowlby, Mark [1 ]
Peri, Ravikumar [1 ]
Vasilyev, Dmytro [1 ]
Arias, Robert [1 ]
机构
[1] Wyeth Res, Neurosci Discovery Res, Princeton, NJ 08543 USA
关键词
D O I
10.1038/nrd2552
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Ion channels represent highly attractive targets for drug discovery and are implicated in a diverse range of disorders, in particular in the central nervous and cardiovascular systems. Moreover, assessment of cardiac ion-channel activity of new chemical entities is now an integral component of drug discovery programmes to assess potential for cardiovascular side effects. Despite their attractiveness as drug discovery targets ion channels remain an under-exploited target class, which is in large part due to the labour-intensive and low-throughput nature of patch-clamp electrophysiology. This Review provides an update on the current state-of-the-art for the various automated electrophysiology platforms that are now available and critically evaluates their impact in terms of ion-channel screening, lead optimization and the assessment of cardiac ion-channel safety liability.
引用
收藏
页码:358 / 368
页数:11
相关论文
共 87 条
[41]   Alterations in synaptic transmission and long-term potentiation in hippocampal slices from young and aged PDAPP mice [J].
Larson, J ;
Lynch, G ;
Games, D ;
Seubert, P .
BRAIN RESEARCH, 1999, 840 (1-2) :23-35
[42]   Flip the tip:: An automated, high quality, cost-effective patch clamp screen [J].
Lepple-Wienhues, A ;
Ferlinz, K ;
Seeger, A ;
Schäfer, A .
RECEPTORS & CHANNELS, 2003, 9 (01) :13-17
[43]  
Lü Q, 2006, DRUG DISCOV SER, V5, P343
[44]   Long-term potentiation and memory [J].
Lynch, MA .
PHYSIOLOGICAL REVIEWS, 2004, 84 (01) :87-136
[45]  
MADISON DV, 1991, ANNU REV NEUROSCI, V14, P379, DOI 10.1146/annurev.ne.14.030191.002115
[46]   In vitro cortical neuronal networks as a new high-sensitive system for biosensing applications [J].
Martinoia, S ;
Bonzano, L ;
Chiappalone, A ;
Tedesco, A ;
Marcoli, A ;
Maura, G .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (10) :2071-2078
[47]   QPatch: the past, present and future of automated patch clamp [J].
Mathes, C .
EXPERT OPINION ON THERAPEUTIC TARGETS, 2006, 10 (02) :319-327
[48]  
MCIIWAIN H, 1975, PRAPARING NEURAL TIS
[49]  
Meyer T, 2004, ASSAY DRUG DEV TECHN, V2, P507, DOI 10.1089/adt.2004.2.507
[50]   Micro-electrode arrays in cardiac safety pharmacology -: A novel tool to study QT interval prolongation [J].
Meyer, T ;
Boven, KH ;
Günther, E ;
Fejtl, M .
DRUG SAFETY, 2004, 27 (11) :763-772