Three-dimensional navigator coronary MRA with the aid of a blood pool agent in pigs: Improved image quality with inclusion of the contrast agent first-pass

被引:5
作者
Dirksen, MS
Kaandorp, TAM
Lamb, HJ
Doornbos, J
Corot, C
de Roos, A
机构
[1] Leiden Univ, Med Ctr, Dept Radiol, NL-2333 ZA Leiden, Netherlands
[2] Guerbet Res, Aulnay Sous Bois, France
关键词
magnetic resonance imaging; coronary arteries; contrast agent; bolus timing; first-pass;
D O I
10.1002/jmri.10389
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the effect of including the first-pass of a blood pool agent (BPA) on the image quality of three-dimensional navigator coronary MRA. Materials and Methods: A pig model was used to perform: 1) T1 simulation of the BPA, based on actual blood samples, and 2) BPA-enhanced three-dimensional navigator coronary MRA, with or without inclusion of the first-pass of the BPA. The acquisitions with inclusion of the first-pass were timed with the use of a test bolus. The acquisitions without first-pass were started one minute after bolus injection (steady-state). A gradient echo acquisition technique with centric k-space sampling was applied. Comparison of both acquisitions was based on determination of contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), and vessel length. Results: T1 simulation shows a distinct T1 reduction during first-pass (to a level below 50 msec), increasing to 190 msec during steady-state. Images obtained with first-pass inclusion showed improved CNR (8.6 +/- 1.7 vs. 4.5 +/- 1.8), SNR (11.9 +/- 1.6 vs. 7.4 +/- 2.0), and vessel length (99.2 +/- 10.9 mm vs. 60.5 +/- 21.8 mm) as compared to the acquisitions during steady-state only (all: P< 0.05). Conclusion: The image quality of three-dimensional navigator coronary MRA combined with a gadolinium BPA in pigs is improved when starting the image acquisition during first-pass of the bolus.
引用
收藏
页码:502 / 506
页数:5
相关论文
共 21 条
[1]   Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA [J].
Botnar, RM ;
Stuber, M ;
Danias, PG ;
Kissinger, KV ;
Manning, WJ .
CIRCULATION, 1999, 99 (24) :3139-3148
[2]   Steady-state and dynamic MR angiography with MS-325: Initial experience in humans [J].
Grist, TM ;
Korosec, FR ;
Peters, DC ;
Witte, S ;
Walovitch, RC ;
Dolan, RP ;
Bridson, WE ;
Yucel, EK ;
Mistretta, CA .
RADIOLOGY, 1998, 207 (02) :539-544
[3]  
Hofman MBM, 1999, MAGN RESON MED, V41, P360, DOI 10.1002/(SICI)1522-2594(199902)41:2<360::AID-MRM21>3.0.CO
[4]  
2-C
[5]   Coronary arteries: MR angiography with fast contrast-enhanced three-dimensional breath-hold imaging - Initial experience [J].
Kessler, W ;
Laub, G ;
Achenbach, S ;
Ropers, D ;
Moshage, W ;
Daniel, WG .
RADIOLOGY, 1999, 210 (02) :566-572
[6]   Three-dimensional MRI of coronary arteries using an intravascular contrast agent [J].
Li, DB ;
Dolan, RP ;
Walovitch, RC ;
Lauffer, RB .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (06) :1014-1018
[7]   Coronary arteries: Magnetization-prepared contrast-enhanced three-dimensional volume-targeted breath-hold MR angiography [J].
Li, DB ;
Carr, JC ;
Shea, SM ;
Zheng, J ;
Deshpande, VS ;
Wielopolski, PA ;
Finn, JP .
RADIOLOGY, 2001, 219 (01) :270-277
[8]   Contrast-enhanced MR imaging of coronary arteries: Comparison of intra- and extravascular contrast agents in swine [J].
Li, DB ;
Zheng, J ;
Weinmann, HJ .
RADIOLOGY, 2001, 218 (03) :670-678
[9]   Pharmacokinetics of Gadomer-17, a new dendritic magnetic resonance contrast agent [J].
Misselwitz, B ;
Schmitt-Willich, H ;
Ebert, W ;
Frenzel, T ;
Weinmann, HJ .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2001, 12 (2-3) :128-134
[10]   CARDIOVASCULAR MR-IMAGING - PRESSURE-GATING USING THE ARTERIAL-PRESSURE SIGNAL FROM A CONVENTIONAL FERROMAGNETIC MICROMANOMETER-TIP CATHETER [J].
PATTYNAMA, PMT ;
VANDERVELDE, ET ;
STEENDIJK, P ;
LAMB, HJ ;
BAAN, J ;
DEROOS, A .
MAGNETIC RESONANCE IMAGING, 1994, 12 (03) :531-534