Three-dimensional MRI of coronary arteries using an intravascular contrast agent

被引:85
作者
Li, DB
Dolan, RP
Walovitch, RC
Lauffer, RB
机构
[1] Washington Univ, Sch Med, Edward Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
[2] EPIX Med Inc, Cambridge, MA USA
关键词
MRI; coronary vessels; contrast agents; animal studies;
D O I
10.1002/mrm.1910390621
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To assess the effectiveness of an intravascular contrast agent, MS-325, for enhancing the vascular signal in coronary MR angiograms, six minipigs were studied using a three-dimensional, gradient-echo sequence with retrospective respiratory gating. To suppress the myocardial signal, preparatory RF pulses were applied before data acquisition. With the administration of MS-325, the blood signal-to-noise ratio increased by 97-276%, depending on the region of interest in which the blood signal was measured and the precontrast imaging sequence structures. The blood/myocardium contrast-to-noise ratio also significantly increased. High-resolution images (0.58 x 0.58 x 1 mm(3)) obtained from postmortem pig hearts demonstrated the potential delineation of coronary arteries with MS-325. In conclusion, this study supports further evaluation of the utility of MS-325 in improving coronary MR angiography in humans.
引用
收藏
页码:1014 / 1018
页数:5
相关论文
共 15 条
[1]   DYNAMIC CONTRAST-ENHANCED SUBTRACTION MR-ANGIOGRAPHY OF THE LOWER-EXTREMITIES - INITIAL EVALUATION WITH A MULTISECTION 2-DIMENSIONAL TIME-OF-FLIGHT SEQUENCE [J].
ADAMIS, MK ;
LI, W ;
WIELOPOLSKI, PA ;
KIM, D ;
SAX, EJ ;
KENT, KC ;
EDELMAN, RR .
RADIOLOGY, 1995, 196 (03) :689-695
[2]   CORONARY ANGIOGRAPHY WITH MAGNETIZATION-PREPARED T-2 CONTRAST [J].
BRITTAIN, JH ;
HU, BS ;
WRIGHT, GA ;
MEYER, CH ;
MACOVSKI, A ;
NISHIMURA, DG .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :689-696
[3]   3D gadolinium-enhanced MR angiography of the carotid arteries [J].
Cloft, HJ ;
Murphy, KJ ;
Prince, MR ;
Brunberg, JA .
MAGNETIC RESONANCE IMAGING, 1996, 14 (06) :593-600
[4]   CORONARY-ARTERY IMAGING IN MULTIPLE 1-SEC BREATH HOLDS [J].
DOYLE, M ;
SCHEIDEGGER, MB ;
DEGRAAF, RG ;
VERMEULEN, J ;
POHOST, GM .
MAGNETIC RESONANCE IMAGING, 1993, 11 (01) :3-6
[5]  
GOLDFARB JW, 1997, P ISMRM 5 ANN M VANC, P200
[6]   Pulmonary perfusion and angiography: Evaluation with breath-hold enhanced three-dimensional fast imaging steady-state precession MR imaging with short TR and TE [J].
Hatabu, H ;
Gaa, J ;
Kim, D ;
Li, W ;
Prasad, PV ;
Edelman, RR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (03) :653-655
[7]  
HOFMAN MBM, 1997, P ISMRM 5 ANN M VANC, P442
[8]   Time-resolved contrast-enhanced 3D MR angiography [J].
Korosec, FR ;
Frayne, R ;
Grist, TM ;
Mistretta, CA .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (03) :345-351
[9]   MS-325: A small-molecule vascular imaging agent for magnetic resonance imaging [J].
Lauffer, RB ;
Parmelee, DJ ;
Ouellet, HS ;
Dolan, RP ;
Sajiki, H ;
Scott, DM ;
Bernard, PJ ;
Buchanan, EM ;
Ong, KY ;
Tyeklar, Z ;
Midelfort, KS ;
McMurry, TJ ;
Walovitch, RC .
ACADEMIC RADIOLOGY, 1996, 3 :S356-S358
[10]   CORONARY-ARTERIES - 3-DIMENSIONAL MR-IMAGING WITH FAT SATURATION AND MAGNETIZATION TRANSFER CONTRAST [J].
LI, D ;
PASCHAL, CB ;
HAACKE, EM ;
ADLER, LP .
RADIOLOGY, 1993, 187 (02) :401-406