Radiation damage of silicon strip detectors in the NA50 experiment

被引:2
作者
Alessandro, B
Beolé, S
Bonazzola, G
Crescio, E
Dabrowski, W
Giubellino, P
Grybos, P
Idzik, M
Martinetto, M
Marzari-Chiesa, A
Masera, M
Prino, F
Ramello, L
Mendes, PR
Riccati, L
Sitta, M
机构
[1] Acad Min & Met, Fac Phys & Nucl Tech, PL-30059 Krakow, Poland
[2] Ist Nazl Fis Nucl, I-10125 Turin, Italy
关键词
silicon strip detectors; noisy channels; radiation damage;
D O I
10.1016/S0168-9002(98)00868-7
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
During operation of the multiplicity detector in the NA50 experiment the single sided AC-coupled p-on-n silicon strip detectors were exposed to charged particle fluences up to 20(14) eq n/cm(2) and ionising doses up to 20 Mrad, with a very non-uniform radiation spatial distribution. Radiation effects in the detectors observed during the '96 lead ion run as well as results of the post-run measurements are presented in this paper. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:556 / 569
页数:14
相关论文
共 7 条
[1]   Design and operation of a fast high-granularity silicon detector system in a high-radiation environment [J].
Alessandro, B ;
Alexeline, M ;
Baglin, C ;
Beole, S ;
Bollito, E ;
Bonazzola, G ;
Bussiere, A ;
Capony, V ;
Dabrowski, W ;
De Remigis, P ;
De Witt, J ;
Forlen, M ;
Giubellino, P ;
Idzik, M ;
Marzari-Chiesa, A ;
Masera, M ;
da Silva, WP ;
Ramello, L ;
Mendes, PR ;
Riccati, L ;
Sartori, MS ;
Sitta, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 409 (1-3) :167-172
[2]  
ANDRICEK L, 1997, INDETNO191 ATLAS
[3]  
BEATTIE LJ, 1997, INDETNO194 ATLAS
[4]  
*CERN LHCC, CERNLHCC9717 ATLAS, V2, P394
[5]  
DABROWSKI W, 1989, NUCL INSTRUM METH A, V276, P270, DOI 10.1016/0168-9002(89)90644-X
[6]   Experimental results on radiation induced bulk damage effects in float-zone and epitaxial silicon detectors [J].
Dezillie, B ;
Lemeilleur, F ;
Glaser, M ;
Casse, GL ;
Leroy, C .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 386 (01) :162-166
[7]   RADIATION EFFECTS OF DOUBLE-SIDED SILICON STRIP SENSORS [J].
TAMURA, N ;
HATAKENAKA, T ;
IWATA, Y ;
KUBOTA, M ;
OHSUGI, T ;
OKADA, M ;
UNNO, Y ;
ASO, T ;
ISHIZUKA, M ;
MIYATA, H ;
ANDO, A ;
HATANAKA, K ;
MIZUNO, Y ;
GOTO, M ;
KOBAYASHI, S ;
MURAKAMI, A ;
INOUE, K ;
SUZUKI, Y ;
DAIGO, M ;
YAMAMOTO, K ;
YAMAMURA, K .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 342 (01) :131-136