Treatment planning for lung cancer: Traditional homogeneous point-dose prescription compared with heterogeneity-corrected dose-volume prescription

被引:22
作者
Frank, SJ
Forster, KM
Stevens, CW
Cox, JD
Komaki, R
Liao, ZX
Tucker, S
Wang, XM
Steadham, RE
Brooks, C
Starkschall, G
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
[2] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[3] Univ Texas, MD Anderson Canc Ctr, Dept Biomath, Houston, TX 77030 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2003年 / 56卷 / 05期
关键词
heterogeneity corrections; lung cancer; treatment planning;
D O I
10.1016/S0360-3016(03)00337-7
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To quantify the differences in doses to target volumes and critical thoracic structures calculated by traditional homogeneous point-dose prescription and heterogeneity-corrected volume-dose prescription. Methods and Materials: Between 1998 and 2001, 30 patients with inoperable Stage I/II non-small-cell lung cancer underwent radiation treatment planning at our institution. A commercially available convolution/superposition- based algorithm was used. Three treatment plans were calculated for each patient using identical beam geometries: one plan was generated by traditional homogeneous point-dose prescription, a second by the traditional method with heterogeneity correction, and a third by heterogeneity-corrected volume-dose prescription that would cover 95% of the planned target volume (PTV). Target volume coverage, isocenter dose, and dose uniformity in the second and third plans were compared. Results: The PTV, clinical target volume (CTV), and isocenter calculated by the heterogeneity-corrected volume-dose method were equivalent to those calculated by the traditional homogeneous point-dose method with heterogeneity correction. The fraction of the PTV covered by heterogeneity-corrected volume-dose prescription was significantly greater than the fraction covered by traditional homogeneous point-dose prescription with heterogeneity correction (p = 0.05). The dose prescribed using the traditional method would have been delivered to less than 90% of the PTV in 14 of 30 patients. There was no significant difference in the maximum and minimum doses to the PTV, the CTV, or the isocenter calculated by the traditional homogeneous method with heterogeneity correction and the heterogeneity-corrected volume-dose method. There was also no significant difference in the planned volume of lung receiving greater than 20 Gy as calculated by these two methods. Conclusion: When compared with traditional homogeneous radiation treatment planning, heterogeneity-corrected methods produce equivalent PTV, CTV, and isocenter doses while providing superior PTV coverage. (C) 2003 Elsevier Inc.
引用
收藏
页码:1308 / 1318
页数:11
相关论文
共 19 条
[1]  
GIFFORD KA, 2001, J APPL CLIN MED PHYS, V3, P26
[2]   Evaluation of microscopic tumor extension in non-small-cell lung cancer for three-dimensional conformal radiotherapy planning [J].
Giraud, P ;
Antoine, M ;
Larrouy, A ;
Milleron, B ;
Callard, P ;
De Rycke, Y ;
Carette, MF ;
Rosenwald, JC ;
Cosset, JM ;
Housset, M ;
Touboul, E .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (04) :1015-1024
[3]   Clinical dose-volume histogram analysis for pneumonitis after 3D treatment for non-small cell lung cancer (NSCLC) [J].
Graham, MV ;
Purdy, JA ;
Emami, B ;
Harms, W ;
Bosch, W ;
Lockett, MA ;
Perez, CA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (02) :323-329
[4]  
International Commission in Radiation Units and Measurements, 1993, 50 ICRU
[5]   A volumetric study of measurements and calculations of lung density corrections for 6 and 18 MV photons [J].
Klein, EE ;
Morrison, A ;
Purdy, JA ;
Graham, MV ;
Matthews, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 37 (05) :1163-1170
[6]   THE INFLUENCE OF AIR CAVITIES ON INTERFACE DOSES FOR PHOTON BEAMS [J].
KLEIN, EE ;
CHIN, LM ;
RICE, RK ;
MIJNHEER, BJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 (02) :419-427
[7]  
LEHMANN EL, 1975, NONPARAMETRICS STATI, P125
[8]   LUNG DOSE CORRECTIONS FOR 6-MV AND 15-MV X-RAYS [J].
MACKIE, TR ;
ELKHATIB, E ;
BATTISTA, J ;
SCRIMGER, J ;
VANDYK, J ;
CUNNINGHAM, JR .
MEDICAL PHYSICS, 1985, 12 (03) :327-332
[9]  
MANTEL N, 1966, CANC CHEMOTHER REP, V60, P163
[10]   Study of lung density corrections in a clinical trial (RTOG 88-08) [J].
Orton, CG ;
Chungbin, S ;
Klein, EE ;
Gillin, MT ;
Schultheiss, TE ;
Sause, WT .