A charge coupled device camera with electron decelerator for intermediate voltage electron microscopy

被引:14
作者
Downing, Kenneth H. [1 ]
Mooney, Paul E. [2 ]
机构
[1] Lawrence Berkeley Natl Lab, Donner Lab, Div Life Sci, Berkeley, CA 94720 USA
[2] Gatan Inc, Pleasanton, CA 94588 USA
关键词
D O I
10.1063/1.2902853
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Electron microscopists are increasingly turning to intermediate voltage electron microscopes (IVEMs) operating at 300-400 kV for a wide range of studies. They are also increasingly taking advantage of slow-scan charge coupled device (CCD) cameras, which have become widely used on electron microscopes. Under some conditions, CCDs provide an improvement in data quality over photographic film, as well as the many advantages of direct digital readout. However, CCD performance is seriously degraded on IVEMs compared to the more conventional 100 kV microscopes. In order to increase the efficiency and quality of data recording on IVEMs, we have developed a CCD camera system in which the electrons are decelerated to below 100 kV before impacting the camera, resulting in greatly improved performance in both signal quality and resolution compared to other CCDs used in electron microscopy. These improvements will allow high-quality image and diffraction data to be collected directly with the CCD, enabling improvements in data collection for applications including high-resolution electron crystallography, single particle reconstruction of protein structures, tomographic studies of cell ultrastructure, and remote microscope operation. This approach will enable us to use even larger format CCD chips that are being developed with smaller pixels. (C) 2008 American Institute of Physics.
引用
收藏
页数:10
相关论文
共 28 条
[1]   Assessing the capabilities of a 4kx4k CCD camera for electron cryo-microscopy at 300kV [J].
Booth, Christopher R. ;
Jakana, Joanita ;
Chiu, Wah .
JOURNAL OF STRUCTURAL BIOLOGY, 2006, 156 (03) :556-563
[2]   Leginon: An automated system for acquisition of images from vitreous ice specimens [J].
Carragher, B ;
Kisseberth, N ;
Kriegman, D ;
Milligan, RA ;
Potter, CS ;
Pulokas, J ;
Reilein, A .
JOURNAL OF STRUCTURAL BIOLOGY, 2000, 132 (01) :33-45
[3]   MRC image processing programs [J].
Crowther, RA ;
Henderson, R ;
Smith, JM .
JOURNAL OF STRUCTURAL BIOLOGY, 1996, 116 (01) :9-16
[4]   Development and performance of a fast fibre-plate coupled CCD camera at medium energy and image processing system for electron holography [J].
Daberkow, I ;
Herrmann, KH ;
Liu, L ;
Rau, WD ;
Tietz, H .
ULTRAMICROSCOPY, 1996, 64 (1-4) :35-48
[5]   PERFORMANCE OF ELECTRON IMAGE CONVERTERS WITH YAG SINGLE-CRYSTAL SCREEN AND CCD SENSOR [J].
DABERKOW, I ;
HERRMANN, KH ;
LIU, LB ;
RAU, WD .
ULTRAMICROSCOPY, 1991, 38 (3-4) :215-223
[6]   IMAGING PROPERTIES AND APPLICATIONS OF SLOW-SCAN CHARGE-COUPLED-DEVICE CAMERAS SUITABLE FOR ELECTRON-MICROSCOPY [J].
DERUIJTER, WJ .
MICRON, 1995, 26 (03) :247-275
[7]   Performance of a 2k CCD camera designed for electron crystallography at 400 kV [J].
Downing, KH ;
Hendrickson, FM .
ULTRAMICROSCOPY, 1999, 75 (04) :215-233
[8]   AUTOMATIC FOCUS CORRECTION FOR SPOT-SCAN IMAGING OF TILTED SPECIMENS [J].
DOWNING, KH .
ULTRAMICROSCOPY, 1992, 46 (1-4) :199-206
[9]   ASIC-based event-driven 2D digital electron counter for TEM imaging [J].
Fan, GY ;
Datte, P ;
Beuville, E ;
Beche, JF ;
Millaud, J ;
Downing, KH ;
Burkard, FT ;
Ellisman, MH ;
Xuong, NH .
ULTRAMICROSCOPY, 1998, 70 (03) :107-113
[10]   Cooled CCD camera with tapered fibre optics for electron microscopy [J].
Faruqi, AR ;
Andrews, HN .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 392 (1-3) :233-236