Detection of trace phenol based on mesoporous silica derived tyrosinase-peroxidase biosensor

被引:38
作者
Dai, ZH
Xu, XX
Wu, L
Ju, HX [1 ]
机构
[1] Nanjing Univ, Dept Chem, Educ Minist China, Key Lab Analyt Chem Life Sci, Nanjing 210093, Peoples R China
[2] Nanjing Normal Univ, Dept Chem, Nanjing 210097, Peoples R China
[3] Changshu Coll Jiangsu, Dept Chem, Changshu 215500, Peoples R China
关键词
biosensors; tyrosinase; horseradish peroxidase; phenol; mesoporous silica;
D O I
10.1002/elan.200403256
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel electrochemical biosensor for phenol based on immobilization of tyrosinase-peroxidase on mesoporous silica is described. The enhanced sensitivity of the tyrosinase-horseradish peroxidase based biosensor to phenol was observed on comparing with tyrosinase or horseradish peroxidase monoenzyme modified electrodes. Two enzymes retained their enzymatic activities for phenol determination without any mediator. The preparation conditions of the biosensor are discussed. Optimization of the experimental parameters was performed with regard to pH and operating potential. The phenol sensor exhibited a fast response of less than 10 seconds. The sensitivity of the biosensor for phenol was 14 mu A mu M-1 cm(-2) with a linear range from 2 x 10(-7) to 2.3 x 10(-4) M and a detection limit of 4.1 x 10(-9) M. The biosensor showed a good stability and reproducibility.
引用
收藏
页码:1571 / 1577
页数:7
相关论文
共 42 条
[11]   Adsorption and activity of proteins onto mesoporous silica [J].
Deere, J ;
Magner, E ;
Wall, JG ;
Hodnett, BK .
CATALYSIS LETTERS, 2003, 85 (1-2) :19-23
[12]   Potential applications of oxidative enzymes and phenoloxidase-like compounds in wastewater and soil treatment:: a review [J].
Durán, N ;
Esposito, E .
APPLIED CATALYSIS B-ENVIRONMENTAL, 2000, 28 (02) :83-99
[13]  
Fan CH, 2000, ELECTROANAL, V12, P1156, DOI 10.1002/1521-4109(200010)12:14<1156::AID-ELAN1156>3.0.CO
[14]  
2-4
[15]   Direct electrochemistry of cytochrome c at a glassy carbon electrode covered with a microporous alumina membrane [J].
Ikeda, O ;
Ohtani, M ;
Yamaguchi, T ;
Komura, A .
ELECTROCHIMICA ACTA, 1998, 43 (08) :833-839
[16]  
Kisler JM, 2001, MICROPOR MESOPOR MAT, V44, P769
[17]  
Lei CH, 1999, ELECTROANAL, V11, P274, DOI 10.1002/(SICI)1521-4109(199904)11:4<274::AID-ELAN274>3.0.CO
[18]  
2-G
[19]   Hydrogen peroxide sensor based on coimmobilized methylene green and horseradish peroxidase in the same montmorillonite-modified bovine serum albumin-glutaraldehyde matrix on a glassy carbon electrode surface [J].
Lei, CH ;
Deng, JQ .
ANALYTICAL CHEMISTRY, 1996, 68 (19) :3344-3349
[20]   Silica sol-gel immobilized amperometric biosensor for the determination of phenolic compounds [J].
Li, J ;
Chia, LS ;
Goh, NK ;
Tan, SN .
ANALYTICA CHIMICA ACTA, 1998, 362 (2-3) :203-211