Counting and sizing of particles and particle agglomerates in a microfluidic device using laser light scattering: application to a particle-enhanced immunoassay

被引:99
作者
Pamme, N [1 ]
Koyama, R [1 ]
Manz, A [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Dept Chem, London SW7 2AY, England
关键词
D O I
10.1039/b300876b
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A microfluidic device for counting and sizing particles and particle agglomerates based on laser light scattering is demonstrated. The particles were confined hydrodynamically and passed through a focused laser beam. Scattering at two different angles, 15degrees and 45degrees, was detected. At an acquisition rate of 10 kHz, a throughput of 150 particles s(-1) was achieved. Scattering intensity was found to depend on particle volume for 2 to 9 mum diameter particles. Size discrimination of particles with a diameter ratio of 1 : 2 was accomplished. In addition, the scattering signals of particle agglomerates formed in a particle-enhanced immunoassay for C-reactive protein (CRP) were measured. Scattering intensity was found to be dependent on the CRP concentration, 100 ng CRP per mL could be detected. The particle counting method presented is generic and can be employed in a wide variety of assays as well as for cell counting and particle counting.
引用
收藏
页码:187 / 192
页数:6
相关论文
共 43 条
[1]   Micro total analysis systems. 2. Analytical standard operations and applications [J].
Auroux, PA ;
Iossifidis, D ;
Reyes, DR ;
Manz, A .
ANALYTICAL CHEMISTRY, 2002, 74 (12) :2637-2652
[2]   Modular concept of a laboratory on a chip for chemical and biochemical analysis [J].
Blankenstein, G ;
Larsen, UD .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (3-4) :427-438
[3]  
Bohren C. F., 1998, ABSORPTION SCATTERIN
[4]   Development of a multichannel microfluidic analysis system employing affinity capillary electrophoresis for immunoassay [J].
Cheng, SB ;
Skinner, CD ;
Taylor, J ;
Attiya, S ;
Lee, WE ;
Picelli, G ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 2001, 73 (07) :1472-1479
[5]  
COLLETCASSART D, 1983, CLIN CHEM, V29, P1127
[7]   A microfabricated fluorescence-activated cell sorter [J].
Fu, AY ;
Spence, C ;
Scherer, A ;
Arnold, FH ;
Quake, SR .
NATURE BIOTECHNOLOGY, 1999, 17 (11) :1109-1111
[8]   Micromachined impedance spectroscopy flow cytometer for cell analysis and particle sizing [J].
Gawad, S ;
Schild, L ;
Renaud, P .
LAB ON A CHIP, 2001, 1 (01) :76-82
[9]   FLOW-CYTOMETRY [J].
GILMANSACHS, A .
ANALYTICAL CHEMISTRY, 1994, 66 (13) :A700-A707
[10]   Integrated microchip-device for the digestion, separation and postcolumn labeling of proteins and peptides [J].
Gottschlich, N ;
Culbertson, CT ;
McKnight, TE ;
Jacobson, SC ;
Ramsey, JM .