Real-time catheter tracking and adaptive imaging

被引:41
作者
Elgort, DR
Wong, EY
Hillenbrand, CM
Wacker, FK
Lewin, JS
Duerk, JL
机构
[1] Univ Hosp Cleveland, Dept Radiol, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
关键词
catheter tracking; interventional MRI; adaptive image parameters; real-time imaging; vascular MRI;
D O I
10.1002/jmri.10402
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the performance of a real-time MR system for interventional procedures that adjusts specific image parameters in real time based on a catheter's speed of insertion. Materials and Methods: The system was implemented using only the hardware provided with a standard short-bore 1.5 T scanner (Siemens Magnetom Sonata) (with the exception of small tracking markers affixed to the catheter). The system tracks the position of an MR microcoil-instrumented catheter and automatically updates the scan plane's position and orientation, as well as other features, including, but not limited to, field of view, resolution, tip angle, and TE. A real-time feedback loop continuously localizes the tracking markers, updates the scan plane position and orientation, calculates the catheter's speed, adjusts the value of specific image parameters, then collects new image data, reconstructs an image, and provides it for immediate display. The system was evaluated in phantom and in vivo porcine experiments. Results: The system is able to accurately localize a moving catheter in the abdominal aorta, calculate the device speed, and respond by adjusting specified image parameters 98% of the time. with precision of approximately 2 mm and 1.5degrees. Conclusion: Simply slowing the speed of the catheter allows the clinician to adjust predetermined image parameters. This work also has the potential to build a degree of intelligence into the scanner, enabling it to react to changes in the clinical environment and automatically optimize specific image parameters.
引用
收藏
页码:621 / 626
页数:6
相关论文
共 26 条
[1]   Catheter-tracking FOV MR fluoroscopy [J].
Atalar, E ;
Kraitchman, DL ;
Carkhuff, B ;
Lesho, J ;
Ocali, O ;
Solaiyappan, M ;
Guttman, MA ;
Charles, HK .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (06) :865-872
[2]  
Busse RF, 1999, MAGNET RESON MED, V41, P846, DOI 10.1002/(SICI)1522-2594(199904)41:4<846::AID-MRM26>3.0.CO
[3]  
2-L
[4]   Integrated and interactive position tracking and imaging of interventional tools and internal devices using small fiducial receiver coils [J].
Coutts, GA ;
Gilderdale, DJ ;
Chui, M ;
Kasuboski, L ;
DeSouza, NM .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (06) :908-913
[5]   Dynamic scan-plane tracking using MR position monitoring [J].
Derbyshire, JA ;
Wright, GA ;
Henkelman, RM ;
Hinks, RS .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (04) :924-932
[6]   A brief review of hardware for catheter tracking in magnetic resonance imaging [J].
Duerk, JL ;
Wong, EY ;
Lewin, JS .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2002, 13 (03) :199-208
[7]   REAL-TIME POSITION MONITORING OF INVASIVE DEVICES USING MAGNETIC-RESONANCE [J].
DUMOULIN, CL ;
SOUZA, SP ;
DARROW, RD .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (03) :411-415
[8]   A method for fast 3D tracking using tuned fiducial markers and a limited projection reconstruction FISP (LPR-FISP) sequence [J].
Flask, C ;
Elgort, D ;
Wong, E ;
Shankaranarayanan, A ;
Lewin, J ;
Wendt, M ;
Duerk, JL .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (05) :617-627
[9]   Real-time interactive MRI on a conventional scanner [J].
Kerr, AB ;
Pauly, JM ;
Hu, BS ;
Li, KC ;
Hardy, CJ ;
Meyer, CH ;
Macovski, A ;
Nishimura, DG .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (03) :355-367
[10]  
Ladd ME, 2000, MAGN RESON MED, V43, P615, DOI 10.1002/(SICI)1522-2594(200004)43:4<615::AID-MRM19>3.0.CO