Botulinum toxin type B micromechanosensor

被引:51
作者
Liu, W
Montana, V
Chapman, ER
Mohideen, U [1 ]
Parpura, V
机构
[1] Univ Calif Riverside, Dept Phys, Riverside, CA 92521 USA
[2] Univ Calif Riverside, Dept Cell Biol & Neurosci, Riverside, CA 92521 USA
[3] Univ Calif Riverside, Ctr Nanoscale Sci & Engn, Riverside, CA 92521 USA
[4] Univ Wisconsin, Dept Physiol, Madison, WI 53706 USA
关键词
D O I
10.1073/pnas.2233819100
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Botulinum neurotoxin (BoNT) types A, B, E, and F are toxic to humans; early and rapid detection is essential for adequate medical treatment. Presently available tests for detection of BoNTs, although sensitive, require hours to days. We report a BoNT-B sensor whose properties allow detection of BoNT-B within minutes. The technique relies on the detection of an agarose bead detachment from the tip of a micromachined cantilever resulting from BoNT-B action on its substratum, the synaptic protein synaptobrevin 2, attached to the beads. The mechanical resonance frequency of the cantilever is monitored for the detection. To suspend the bead off the cantilever we use synaptobrevin's molecular interaction with another synaptic protein, syntaxin 1A, that was deposited onto the cantilever tip. Additionally, this bead detachment technique is general and can be used in any displacement reaction, such as in receptor-ligand pairs, where the introduction of one chemical leads to the displacement of another. The technique is of broad interest and will find uses outside toxicology.
引用
收藏
页码:13621 / 13625
页数:5
相关论文
共 28 条
  • [1] Botulinum toxin as a biological weapon - Medical and public health management
    Arnon, SS
    Schechter, R
    Inglesby, TV
    Henderson, DA
    Bartlett, JG
    Ascher, MS
    Eitzen, E
    Fine, AD
    Hauer, J
    Layton, M
    Lillibridge, S
    Osterholm, MT
    O'Toole, T
    Parker, G
    Perl, TM
    Russell, PK
    Swerdlow, DL
    Tonat, K
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2001, 285 (08): : 1059 - 1070
  • [2] A MARKER OF EARLY AMACRINE CELL-DEVELOPMENT IN RAT RETINA
    BARNSTABLE, CJ
    HOFSTEIN, R
    AKAGAWA, K
    [J]. DEVELOPMENTAL BRAIN RESEARCH, 1985, 20 (02): : 286 - 290
  • [3] A high-sensitivity micromachined biosensor
    Baselt, DR
    Lee, GU
    Hansen, KM
    Chrisey, LA
    Colton, RJ
    [J]. PROCEEDINGS OF THE IEEE, 1997, 85 (04) : 672 - 680
  • [4] BERKOW R, 1992, MERCK MANUAL DIAGNOS
  • [5] Demonstration of the lateral Casimir force
    Chen, F
    Mohideen, U
    Klimchitskaya, GL
    Mostepanenko, VM
    [J]. PHYSICAL REVIEW LETTERS, 2002, 88 (10) : 4 - 101801
  • [6] IMAGING CRYSTALS, POLYMERS, AND PROCESSES IN WATER WITH THE ATOMIC FORCE MICROSCOPE
    DRAKE, B
    PRATER, CB
    WEISENHORN, AL
    GOULD, SAC
    ALBRECHT, TR
    QUATE, CF
    CANNELL, DS
    HANSMA, HG
    HANSMA, PK
    [J]. SCIENCE, 1989, 243 (4898) : 1586 - 1589
  • [7] SYNAPTOBREVIN BINDING TO SYNAPTOPHYSIN - A POTENTIAL MECHANISM FOR CONTROLLING THE EXOCYTOTIC FUSION MACHINE
    EDELMANN, L
    HANSON, PI
    CHAPMAN, ER
    JAHN, R
    [J]. EMBO JOURNAL, 1995, 14 (02) : 224 - 231
  • [8] Mixed and non-cognate SNARE complexes - Characterization of assembly and biophysical properties
    Fasshauer, D
    Antonin, W
    Margittai, M
    Pabst, S
    Jahn, R
    [J]. JOURNAL OF BIOLOGICAL CHEMISTRY, 1999, 274 (22) : 15440 - 15446
  • [9] ADHESION FORCES BETWEEN INDIVIDUAL LIGAND-RECEPTOR PAIRS
    FLORIN, EL
    MOY, VT
    GAUB, HE
    [J]. SCIENCE, 1994, 264 (5157) : 415 - 417
  • [10] Translating biomolecular recognition into nanomechanics
    Fritz, J
    Baller, MK
    Lang, HP
    Rothuizen, H
    Vettiger, P
    Meyer, E
    Güntherodt, HJ
    Gerber, C
    Gimzewski, JK
    [J]. SCIENCE, 2000, 288 (5464) : 316 - 318