Inappropriate therapy and fatal proarrhythmia by an implantable cardioverter-defibrittator

被引:75
作者
Vollmann, D [1 ]
Lüthje, L [1 ]
Vonhof, S [1 ]
Unterberg, C [1 ]
机构
[1] Univ Gottingen, Abt Kardiol & Pneumol, Herzzentrum, Dept Cardiol & Pneumol, D-37075 Gottingen, Germany
关键词
implantable cardioverter-defibrillator; inappropriate therapy; proarrhythmia; oversensing; lead failure;
D O I
10.1016/j.hrthm.2004.11.019
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In summary, the present case illustrates the potential proarrhythmic risk associated with ICD therapy. Awareness of this risk is important in light of the growing number of devices implanted for primary prevention of sudden cardiac death. Furthermore, this case emphasizes the importance of lead failure and its early detection. Shock delivery should prompt immediate device interrogation if inappropriate ICD therapy is suspected. © 2005 Heart Rhythm Society. All rights reserved.
引用
收藏
页码:307 / 309
页数:3
相关论文
共 14 条
[1]   Patient alert in implantable cardioverter defibrillators: Toy or tool? [J].
Becker, R ;
Ruf-Richter, J ;
Senges-Becker, JC ;
Bauer, A ;
Weretka, S ;
Voss, F ;
Katus, HA ;
Schoels, W .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (01) :95-98
[2]   Transvenous defibrillation leads: High incidence of failure during long-term follow-up [J].
Dorwarth, U ;
Frey, B ;
Dugas, M ;
Matis, T ;
Fiek, M ;
Schmoeckel, M ;
Remp, T ;
Durchlaub, I ;
Gerth, A ;
Steinbeck, G ;
Hoffmann, E .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2003, 14 (01) :38-43
[3]   Detection and management of an implantable cardioverter defibrillator lead failure - Incidence and clinical implications [J].
Ellenbogen, KA ;
Wood, MA ;
Shepard, RK ;
Clemo, HF ;
Vaughn, T ;
Holloman, K ;
Dow, M ;
Leffler, J ;
Abeyratne, A ;
Verness, D .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (01) :73-80
[4]  
*MEDTR INC, 2004, CRM PROD PERF REP
[5]  
Messali A, 2004, J CARDIOVASC ELECTR, V15, P953, DOI 10.1046/j.1540-8167.2004.03611.x
[6]   THE PROARRHYTHMIC POTENTIAL OF IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS [J].
PINSKI, SL ;
FAHY, GJ .
CIRCULATION, 1995, 92 (06) :1651-1664
[7]   Adverse events with transvenous implantable cardioverter-defibrillators - A prospective multicenter study [J].
Rosenqvist, M ;
Beyer, T ;
Block, M ;
den Dulk, K ;
Minten, J ;
Lindemans, F .
CIRCULATION, 1998, 98 (07) :663-670
[8]  
Schulte B, 1998, Z KARDIOL, V87, P630, DOI 10.1007/s003920050222
[9]   Inappropriate arrhythmia detection in implantable defibrillator therapy due to oversensing of diaphragmatic myopotentials [J].
Schulte, B ;
Sperzel, J ;
Carlsson, J ;
Dürsch, M ;
Erdogan, A ;
Pitschner, HF ;
Neuzner, J .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2001, 5 (04) :487-493
[10]   Early detection of lead fracture by painless high voltage lead impedance measurement in a transvenous ICD lead system [J].
Stevens, J ;
Buchwald, B ;
Krieglstein, H ;
Unterberg, C .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2000, 4 (01) :269-272