Underexpansion of sirollimus-elluting stents: Incidence and relationship to delivery pressure

被引:41
作者
Cheneau, E [1 ]
Satler, LF [1 ]
Escolar, E [1 ]
Suddath, WI [1 ]
Kent, KM [1 ]
Weissman, NJ [1 ]
Waksman, R [1 ]
Pichard, AD [1 ]
机构
[1] Washington Hosp Ctr, Div Cardiol, Washington, DC 20010 USA
关键词
stents; intravascular ultrasound;
D O I
10.1002/ccd.20350
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We aimed to assess the incidence of underexpansion and the relationship between delivery pressure and expansion with sirolimus-eluting stents. Adequate stent expansion contributes to early and late improved outcomes. In 51 patients (53 lesions) with native coronary artery narrowing, balloon-expandable sirolimus-eluting stents (Cypher) were serially expanded with gradual balloon inflations [14 atm, 20 atm, and in case of minimal stent cross-sectional area (CSA)/reference lumen CSA < 50% at 20 atm, postdilatation with 0.5 mm larger balloon]. Intravascular ultrasound (IVUS) imaging was performed before intervention and after each gradual balloon inflation. Stent expansion (minimal stent CSA/reference lumen CSA) was measured. Stent expansion was 72% +/- 16% after 14 atm balloon inflation, 90% +/- 18% after 20 atm balloon inflation (P < 0.001 vs. 14 atm), and 90% +/- 18% at the end of the procedure (including optional postdilatations with 0.5 mm larger balloon; P = NS vs. 20 atm). Stent expansion addressed by MUSIC criteria (all struts apposed, no tissue protrusion, and final lumen CSA > 80% of the reference or > 90% if minimal lumen CSA was < 9 mm(2)) was adequate in 15% of the cases after 14 atm balloon inflation, in 60% after 20 atm balloon inflation (P < 0.001 vs. 14 atm), and in 60% at the end of the procedure (P = NS vs. 20 atm). Sirolimus-eluting stent underexpansion is common when deployed at conventional pressures. Increasing balloon delivery pressure or assessing stent expansion with IVUS seems warranted in order to ensure adequate sirolimus-eluting stent deployment. (c) 2005 Wiley-Liss, Inc.
引用
收藏
页码:222 / 226
页数:5
相关论文
共 14 条
[1]   Predictors of subacute stent thrombosis - Results of a systematic intravascular ultrasound study [J].
Cheneau, E ;
Leborgne, L ;
Mintz, GS ;
Kotani, J ;
Pichard, AD ;
Satler, LF ;
Canos, D ;
Castagna, M ;
Weissman, NJ ;
Waksman, R .
CIRCULATION, 2003, 108 (01) :43-47
[2]  
Cutlip DE, 2001, CIRCULATION, V103, P1967
[3]   Intravascular ultrasound-guided optimized stent deployment - Immediate and 6 months clinical and angiographic results from the Multicenter Ultrasound Stenting in Coronaries Study (MUSIC Study) [J].
de Jaegere, P ;
Mudra, H ;
Figulla, H ;
Almagor, Y ;
Doucet, S ;
Penn, I ;
Colombo, A ;
Hamm, C ;
Bartorelli, A ;
Rothman, M ;
Nobuyoshi, M ;
Yamaguchi, T ;
Voudris, V ;
DiMario, C ;
Makovski, S ;
Hausmann, D ;
Rowe, S ;
Rabinovich, S ;
Sunamura, M ;
van Es, GA .
EUROPEAN HEART JOURNAL, 1998, 19 (08) :1214-1223
[4]   Comparison of luminal enlargement by direct coronary stenting versus predilation coronary stenting by three-dimensional volumetric intravascular ultrasound analysis [J].
Finet, G ;
Weissman, NJ ;
Mintz, GS ;
Satler, LF ;
Kent, KM ;
Castagna, MT ;
Ajani, AE ;
Pichard, AD .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (10) :1179-+
[5]  
*FOOD DRUG ADM, 2003, FDA PAT SAF NEWS NEW
[6]  
*FOOD DRUG ADM, 2003, FDA UPD INF PHYS COR
[7]   Sirolimus-eluting stent implanted in human coronary artery for 16 months - Pathological findings [J].
Guagliumi, G ;
Farb, A ;
Musumeci, G ;
Valsecchi, O ;
Tespili, M ;
Motta, T ;
Virmani, R .
CIRCULATION, 2003, 107 (09) :1340-1341
[8]   Comparison of quantitative coronary angiography, intravascular ultrasound, and coronary pressure measurement to assess optimum stent deployment [J].
Hanekamp, CEE ;
Koolen, JJ ;
Pijls, NHJ ;
Michels, HR ;
Bonnier, HJRM .
CIRCULATION, 1999, 99 (08) :1015-1021
[9]   Intravascular ultrasound predictors of angiographic restenosis in lesions treated with Palmaz-Schatz stents [J].
Hoffmann, R ;
Mintz, GS ;
Mehran, R ;
Pichard, AD ;
Kent, KM ;
Satler, LF ;
Popma, JJ ;
Wu, HS ;
Leon, MB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (01) :43-49
[10]   American College of Cardiology Clinical Expert Consensus Document on Standards for Acquisition, Measurement and Reporting of Intravascular Ultrasound Studies (IVUS) - A report of the American College of Cardiology Task Force on Clinical Expert Consensus - Documents developed in collaboration with the European Society of Cardiology endorsed by the Society of Cardiac Angiography and Interventions [J].
Mintz, GS ;
Nissen, SE ;
Anderson, WD ;
Bailey, SR ;
Erbel, R ;
Fitzgerald, PJ ;
Pinto, FJ ;
Rosenfield, K ;
Siegel, RJ ;
Tuzcu, EM ;
Yock, PG .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (05) :1478-1492