Performance of a portable biosensor for the analysis of organophosphorus and carbamate insecticides in water and food

被引:74
作者
Hildebrandt, A. [1 ]
Bragos, R. [2 ]
Lacorte, S. [1 ]
Marty, J. L. [3 ,4 ]
机构
[1] IIQAB CSIC, Dept Environm Chem, Barcelona, Spain
[2] Univ Politecn Cataluna, Dept Elect Engn, ES-08034 Barcelona, Spain
[3] Univ Perpignan, Ctr Phytopharm, BIOMEM, F-66860 Perpignan, France
[4] Univ Perpignan Via Domitia France, BIOMEM Grp, Perpignan, France
关键词
food; environment; pesticides; biosensor; screen-printed electrodes;
D O I
10.1016/j.snb.2008.02.017
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The performance of a portable biosensor prototype for the determination of neurotoxic pesticides in water and food samples has been assessed and validated for an in-field use. The biosensor is based on the inhibition of the acetylcholinesterase enzyme using screen-printed electrodes and an own designed potentiostat. Quality parameters have been tested using chlorpyrifos-oxon as reference compound. The lower concentration detected was of 2 mu g/L. for an enzymatic charge of 10 mU, the linearity was near to one order of magnitude and the repeatability was of 4.7% (n = 5) at 4 mu g/L. Spiked and non-spiked water samples, beverages and vegetable extracts were used to validate the system and for pepper extracts, the response was compared to HPLC-MS. in these samples, the biosensor was able to detect pesticide concentrations in the order of the tenth of mu g/L, although an important matrix effect was observed which was eliminated by calibrating the system with the same matrix as the sample to be tested. Measured concentrations were comparable to those obtained using commercial laboratory potentiostats and thus the suitability of the biosensor prototype for field application was proved. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:195 / 201
页数:7
相关论文
共 22 条
[1]   GAS-CHROMATOGRAPHIC ANALYSIS OF ORGANOPHOSPHORUS PESTICIDES OF HORTICULTURAL CONCERN [J].
AGUERA, A ;
CONTRERAS, M ;
FERNANDEZALBA, AR .
JOURNAL OF CHROMATOGRAPHY A, 1993, 655 (02) :293-300
[2]   Pesticide determination in tap water and juice samples using disposable amperometric biosensors made using thick-film technology [J].
Albareda-Sirvent, M ;
Merkoçi, A ;
Alegret, S .
ANALYTICA CHIMICA ACTA, 2001, 442 (01) :35-44
[3]   Detection of organophosphorus insecticides with immobilized acetylcholinesterase - comparative study of two enzyme sensors [J].
Andreescu, S ;
Avramescu, A ;
Bala, C ;
Magearu, V ;
Marty, JL .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 374 (01) :39-45
[4]   Screen-printed electrode based on AChE for the detection of pesticides in presence of organic solvents [J].
Andreescu, S ;
Noguer, T ;
Magearu, V ;
Marty, JL .
TALANTA, 2002, 57 (01) :169-176
[5]   Immobilization of acetylcholinesterase on screen-printed electrodes: comparative study between three immobilization methods and applications to the detection of organophosphorus insecticides [J].
Andreescu, S ;
Barthelmebs, L ;
Marty, JL .
ANALYTICA CHIMICA ACTA, 2002, 464 (02) :171-180
[6]   A GENERAL DIGITAL LINEARIZING METHOD FOR TRANSDUCERS [J].
BOLK, WT .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1985, 18 (01) :61-64
[7]   A NEW AND RAPID COLORIMETRIC DETERMINATION OF ACETYLCHOLINESTERASE ACTIVITY [J].
ELLMAN, GL ;
COURTNEY, KD ;
ANDRES, V ;
FEATHERSTONE, RM .
BIOCHEMICAL PHARMACOLOGY, 1961, 7 (02) :88-&
[8]   Monitoring multi-class pesticide residues in fresh fruits and vegetables by liquid chromatography with tandem mass spectrometry [J].
Frenich, AG ;
Vidal, JLM ;
López, TL ;
Aguado, SC ;
Salvador, IM .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1048 (02) :199-206
[9]   Development of a portable biosensor for screening neurotoxic agents in water samples [J].
Hildebrandt, Alain ;
Ribas, Jordi ;
Bragos, Ramon ;
Marty, Jean-Louis ;
Tresanchez, Marius ;
Lacorte, Silvia .
TALANTA, 2008, 75 (05) :1208-1213
[10]   A new multi-residue method for analysis of pesticide residues in fruit and vegetables using liquid chromatography with tandem mass spectrometric detection [J].
Jansson, C ;
Pihlström, T ;
Österdahl, BG ;
Markides, KE .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1023 (01) :93-104