Ultrasensitive proteomics using high-efficiency on-line micro-SPE-NanoLC-NanoESI MS and MS/MS

被引:168
作者
Shen, Y [1 ]
Tolic, N [1 ]
Masselon, C [1 ]
Pasa-Tolic, L [1 ]
Camp, DG [1 ]
Hixson, KK [1 ]
Zhao, R [1 ]
Anderson, GA [1 ]
Smith, RD [1 ]
机构
[1] Pacific NW Natl Lab, Div Biol Sci, Richland, WA 99352 USA
关键词
D O I
10.1021/ac030096q
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ultrasensitive nanoscale proteomics approaches for characterizing proteins from complex proteomic samples of <50 ng of total mass are described. Protein identifications from 0.5 pg of whole proteome extracts were enabled by ultrahigh sensitivity (<75 zmol for individual proteins) achieved using high-efficiency (peak capacities of similar to10(3)) 15-mum-i.d. capillary liquid chromatography separations (i.e., using nanoLC, similar to20 nL/min mobile-phase flow rate at the optimal linear velocity of similar to0.2 cm/s) coupled on-line with a micro-solid-phase sample extraction and a nanoscale electrospray ionization interface to a 11.4-T Fourier transform ion cyclotron resonance (FTICR) mass spectrometer (MS). Proteome measurement coverage improved as sample size was increased from as little as 0.5 pg of sample. It was found that a 2.5-ng sample provided 14% coverage of all annotated open reading frames for the microorganism Deinococcus radiodurans, consistent with previous results for a specific culture condition. The estimated detection dynamic range for detected proteins was 10(5)-10(6). An improved accurate mass and LC elution time two-dimensional data analysis methodology, used to both speed and increase the confidence of peptide/protein identifications, enabled identification of 872 proteins/run from a single 3-h nanoLC/ FTICR MS analysis. The low-zeptomole-level sensitivity provides a basis for extending proteomics studies to smaller cell populations and potentially to a single mammalian cell. Application with ion trap MS/MS instrumentation allowed protein identification from 50 pg (total mass) of proteomic samples (i.e., similar to100 times larger than FTICR MS), corresponding to a sensitivity of similar to7 amol for individual proteins. Compared with single-stage FTICR measurements, ion trap MS/MS provided a much lower proteome measurement coverage and dynamic range for a given analysis time and sample quantity.
引用
收藏
页码:144 / 154
页数:11
相关论文
共 55 条
[31]  
2-7
[32]   Evaluation of multidimensional chromatography coupled with tandem mass spectrometry (LC/LC-MS/MS) for large-scale protein analysis: The yeast proteome [J].
Peng, JM ;
Elias, JE ;
Thoreen, CC ;
Licklider, LJ ;
Gygi, SP .
JOURNAL OF PROTEOME RESEARCH, 2003, 2 (01) :43-50
[33]  
Quadroni M, 1999, ELECTROPHORESIS, V20, P664, DOI 10.1002/(SICI)1522-2683(19990101)20:4/5<664::AID-ELPS664>3.0.CO
[34]  
2-A
[35]   High sensitivity Fourier transform ion cyclotron resonance mass spectrometry for biological analysis with nano-LC and microelectrospray ionization [J].
Quenzer, TL ;
Emmett, MR ;
Hendrickson, CL ;
Kelly, PH ;
Marshall, AG .
ANALYTICAL CHEMISTRY, 2001, 73 (08) :1721-1725
[36]   THE ROLE OF PROTEIN-STRUCTURE IN CHROMATOGRAPHIC BEHAVIOR [J].
REGNIER, FE .
SCIENCE, 1987, 238 (4825) :319-323
[37]   High-efficiency on-line solid-phase extraction coupling to 15-150-μm-id column liquid chromatography for proteomic analysis [J].
Shen, YF ;
Moore, RJ ;
Zhao, R ;
Blonder, J ;
Auberry, DL ;
Masselon, C ;
Pasa-Tolic, L ;
Hixson, KK ;
Auberry, KJ ;
Smith, RD .
ANALYTICAL CHEMISTRY, 2003, 75 (14) :3596-3605
[38]   Packed capillary reversed-phase liquid chromatography with high-performance electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry for proteomics [J].
Shen, YF ;
Zhao, R ;
Belov, ME ;
Conrads, TP ;
Anderson, GA ;
Tang, KQ ;
Pasa-Tolic, L ;
Veenstra, TD ;
Lipton, MS ;
Udseth, HR ;
Smith, RD .
ANALYTICAL CHEMISTRY, 2001, 73 (08) :1766-1775
[39]   High-throughput proteomics using high efficiency multiple-capillary liquid chromatography with on-line high-performance ESI FTICR mass spectrometry [J].
Shen, YF ;
Tolic, N ;
Zhao, R ;
Pasa-Tolic, L ;
Li, LJ ;
Berger, SJ ;
Harkewicz, R ;
Anderson, GA ;
Belov, ME ;
Smith, RD .
ANALYTICAL CHEMISTRY, 2001, 73 (13) :3011-3021
[40]   High-efficiency nanoscale liquid chromatography coupled on-line with mass spectrometry using nanoelectrospray ionization for proteomics [J].
Shen, YF ;
Zhao, R ;
Berger, SJ ;
Anderson, GA ;
Rodriguez, N ;
Smith, RD .
ANALYTICAL CHEMISTRY, 2002, 74 (16) :4235-4249