Biologic and physical fractionation effects of random geometric errors

被引:116
作者
van Herk, M [1 ]
Witte, M [1 ]
van Der Geer, J [1 ]
Schneider, C [1 ]
Lebesque, JV [1 ]
机构
[1] Netherlands Canc Inst, Antoni Van Leeuwenhoek Hosp, Dept Radiotherapy, NL-1066 CX Amsterdam, Netherlands
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2003年 / 57卷 / 05期
关键词
biologic fractionation effects; random errors; respiration;
D O I
10.1016/j.ijrobp.2003.08.026
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: We are developing a system to model the effect of random and systematic geometric errors on radiotherapy delivery. The purpose of this study was to investigate biologic and physical fractionation effects of random geometric errors and respiration motion and compare the resulting dose distributions with Gaussian blurring of the planned dose. Methods and Materials: A hypothetical dose distribution with Gaussian penumbra was used. Random errors drawn from a normal distribution, optionally combined with simulated respiration motion (in the cranio-caudal direction), were used to displace the dose distribution for N simulated fractions. To simulate biologic effects of fractionation, the physical dose was converted to a biologically effective dose using the linear-quadratic model (including repopulation), then summed and converted back to physical dose for comparison. Differences between dose distributions were quantified in terms of the distance between selected isodose levels. Results: A limited number of fractions led to an uncertainty in the position of isodose levels in the total dose with as standard deviation (SD) the SD of the random error divided by rootN. Due to biologic fractionation effects, the total dose distribution became slightly wider: 0.4 mm for alpha/beta = 1 Gy and a random error SD of 3 mm. The widening increased with random error and reduced with increasing alpha/beta but does not depend on the number of fractions or on repopulation. Respiration motion caused an asymmetric deviation in the shape of the total dose distribution, but no additional dose widening was seen from the biologic effect of fractionation. With a random error SD of 3 mm and respiration amplitude, A, of 1 cm or less (SD < 0.36 cm), the asymmetry was negligible. For larger respiration amplitudes (combined with the same random error), the shift of the 95% isodose level was about 0.25*A caudally, and 0.45*A cranially. Conclusions: Gaussian blurring with a combined SD of organ motion, setup error, and respiration motion is a valid approximation for the effect of purely random errors in fractionated radiotherapy. For respiration motion in excess of 1 cm in amplitude, isodose lines shift in a distinctly asymmetric fashion and asymmetric margins need to be used. (C) 2003 Elsevier Inc.
引用
收藏
页码:1460 / 1471
页数:12
相关论文
共 22 条
[1]   A VERIFICATION PROCEDURE TO IMPROVE PATIENT SET-UP ACCURACY USING PORTAL IMAGES [J].
BEL, A ;
VANHERK, M ;
BARTELINK, H ;
LEBESQUE, JV .
RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) :253-260
[2]   The effect of set-up uncertainties, contour changes, and tissue inhomogeneities on target dose-volume histograms [J].
Cho, BCJ ;
van Herk, M ;
Mijnheer, BJ ;
Bartelink, H .
MEDICAL PHYSICS, 2002, 29 (10) :2305-2318
[3]   FAST ALGORITHMS FOR LOW-LEVEL VISION [J].
DERICHE, R .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1990, 12 (01) :78-87
[4]   The effect of breathing and set-up errors on the cumulative dose to a lung tumor [J].
Engelsmann, M ;
Damen, EMF ;
De Jaeger, K ;
van Ingen, KM ;
Mijnheer, BJ .
RADIOTHERAPY AND ONCOLOGY, 2001, 60 (01) :95-105
[5]   Portal imaging to assess set-up errors, tumor motion and tumor shrinkage during conformal radiotherapy of non-small cell lung cancer [J].
Erridge, SC ;
Seppenwoolde, Y ;
Muller, SH ;
van Herk, M ;
De Jaeger, K ;
Belderbos, JSA ;
Boersma, LJ ;
Lebesque, JV .
RADIOTHERAPY AND ONCOLOGY, 2003, 66 (01) :75-85
[6]   Set-up verification using portal imaging; review of current clinical practice [J].
Hurkmans, CW ;
Remeijer, P ;
Lebesque, JV ;
Mijnheer, BJ .
RADIOTHERAPY AND ONCOLOGY, 2001, 58 (02) :105-120
[7]   A numerical simulation of organ motion and daily setup uncertainties: Implications for radiation therapy [J].
Killoran, JH ;
Kooy, HM ;
Gladstone, DJ ;
Welte, FJ ;
Beard, CJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 37 (01) :213-221
[8]   THE SIMULTANEOUS BOOST TECHNIQUE - THE CONCEPT OF RELATIVE NORMALIZED TOTAL DOSE [J].
LEBESQUE, JV ;
KEUS, RB .
RADIOTHERAPY AND ONCOLOGY, 1991, 22 (01) :45-55
[9]   IMPLEMENTATION OF RANDOM POSITIONING ERROR IN COMPUTERIZED RADIATION TREATMENT PLANNING SYSTEMS AS A RESULT OF FRACTIONATION [J].
LEONG, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (03) :327-334
[10]   Inverse planning incorporating organ motion [J].
Li, JG ;
Xing, L .
MEDICAL PHYSICS, 2000, 27 (07) :1573-1578