The effect of set-up uncertainties, contour changes, and tissue inhomogeneities on target dose-volume histograms

被引:48
作者
Cho, BCJ
van Herk, M
Mijnheer, BJ
Bartelink, H
机构
[1] Netherlands Canc Inst, Antoni Van Leeuwenhoek Hosp, Dept Radiotherapy, NL-1066 CX Amsterdam, Netherlands
[2] Cross Canc Inst, Dept Radiat Oncol, Edmonton, AB T6G 1Z2, Canada
关键词
treatment planning; dose-volume histograms; set-up uncertainty; tissue inhomogeneity; interpolation;
D O I
10.1118/1.1508800
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Understanding set-up uncertainty effects on dose distributions is an important clinical problem but difficult to model accurately due to their dependence on tissue inhomogeneities and changes in the surface contour (i.e., variant effects). The aims are: (1) to evaluate and quantify the invariant and variant effects of set-up uncertainties, contour changes and tissue inhomogeneities on target dose-volume histograms (DVHs); (2) to propose a method to interpolate (variant) DVHs. We present a lung cancer patient to estimate the significance of set-up uncertainties, contour changes and tissue inhomogeneities in target DVHs. Differential DVHs are calculated for 15 displacement errors (with respect to the isocenter) using (1) an invariant shift of the dose distribution at the isocenter, (2) a full variant calculation, and (3) a B-spline interpolation applied to sparsely sampled variant DVHs. The collapsed cone algorithm was used for all dose calculations. Dosimetric differences are quantified with the root mean square (RMS) deviation and the equivalent uniform dose (EUD). To determine set-up uncertainty effects, weighted mean EUDs, assuming normally distributed displacement errors, are used. The maximum absolute difference and RMS deviation in the integral DVHs' relative dose between (1) the invariant and calculated curves are 65.2% and 5.8% and (2) the interpolated and calculated curves are 16.9% and 2.5%. Similarly, the maximum absolute difference and RMS deviation in mean EUD as a function of the set-up uncertainty's standard deviation between (1) the invariant and calculated curves are 0.02 and 0.01 Gy; and (2) the interpolated and calculated curves are 0.01 and 0.006 Gy. Since a "worst-case" example is selected, we conclude that, in the majority of clinical cases, the variant effects of contour changes, tissue inhomogeneities and set-up uncertainties on EUD are negligible. Interpolation is a valid, efficient method to approximate DVHs. (C) 2002 American Association of Physicists in Medicine.
引用
收藏
页码:2305 / 2318
页数:14
相关论文
共 28 条
[1]   COLLAPSED CONE CONVOLUTION OF RADIANT ENERGY FOR PHOTON DOSE CALCULATION IN HETEROGENEOUS MEDIA [J].
AHNESJO, A .
MEDICAL PHYSICS, 1989, 16 (04) :577-592
[2]   Target margins for random geometrical treatment uncertainties in conformal radiotherapy [J].
Bel, A ;
vanHerk, M ;
Lebesque, JV .
MEDICAL PHYSICS, 1996, 23 (09) :1537-1545
[3]   Verification of lung dose in an anthropomorphic phantom calculated by the collapsed cone convolution method [J].
Butson, MJ ;
Elferink, R ;
Cheung, T ;
Yu, PKN ;
Stokes, M ;
Quach, KY ;
Metcalfe, P .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (11) :N143-N149
[4]   TOLERANCES IN SETUP AND DOSIMETRIC ERRORS IN THE RADIATION TREATMENT OF BREAST-CANCER [J].
DAS, IJ ;
CHENG, CW ;
FOSMIRE, H ;
KASE, KR ;
FITZGERALD, TJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 26 (05) :883-890
[5]   Comparison of the Batho, ETAR and Monte Carlo dose calculation methods in CT based patient models [J].
du Plessis, FCP ;
Willemse, CA ;
Lötter, MG ;
Goedhals, L .
MEDICAL PHYSICS, 2001, 28 (04) :582-589
[6]   Viability of the EUD and TCP concepts as reliable dose indicators [J].
Ebert, MA .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (02) :441-457
[7]   Impact of simple tissue inhomogeneity correction algorithms on conformal radiotherapy of lung tumours [J].
Engelsman, M ;
Damen, EMF ;
Koken, PW ;
van 't Veld, AA ;
van Ingen, KM ;
Mijnheer, BJ .
RADIOTHERAPY AND ONCOLOGY, 2001, 60 (03) :299-309
[8]   The effect of breathing and set-up errors on the cumulative dose to a lung tumor [J].
Engelsmann, M ;
Damen, EMF ;
De Jaeger, K ;
van Ingen, KM ;
Mijnheer, BJ .
RADIOTHERAPY AND ONCOLOGY, 2001, 60 (01) :95-105
[9]   Photon dose calculation of a three-dimensional treatment planning system compared to the Monte Carlo code BEAM [J].
Francescon, P ;
Cavedon, C ;
Reccanello, S ;
Cora, S .
MEDICAL PHYSICS, 2000, 27 (07) :1579-1587
[10]   A simulation of the effects of set-up error and changes in breast volume on conventional and intensity-modulated treatments in breast radiotherapy [J].
Hector, C ;
Webb, S ;
Evans, PM .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (05) :1451-1471