Impact of simple tissue inhomogeneity correction algorithms on conformal radiotherapy of lung tumours

被引:98
作者
Engelsman, M
Damen, EMF
Koken, PW
van 't Veld, AA
van Ingen, KM
Mijnheer, BJ
机构
[1] Netherlands Canc Inst, Antoni Van Leeuwenhoek Huis, Div Radiotherapy, NL-1066 CX Amsterdam, Netherlands
[2] Vrije Univ Amsterdam, Univ Hosp, Dept Radiat Oncol, Dept Clin Phys & Informat, NL-1007 MB Amsterdam, Netherlands
[3] Univ Groningen Hosp, Dept Radiat Oncol, NL-9700 RB Groningen, Netherlands
关键词
lung cancer; dose calculation; inhomogeneity correction algorithms; beam penumbra;
D O I
10.1016/S0167-8140(01)00387-5
中图分类号
R73 [肿瘤学];
学科分类号
100214 [肿瘤学];
摘要
Background and purpose: Conformal radiotherapy requires accurate dose calculation at the dose specification point, at other points in the planning target volume (PTV) and in organs at risk. To assess the limitations of treatment planning of lung tumours, errors in dose values, calculated by some simple tissue inhomogeneity correction algorithms available in a number of currently applied treatment planning systems, have been quantified. Materials and methods: Single multileaf collimator-shaped photon beams of 6, 8, 15 and 18 MV nominal energy were used to irradiate a 50 mm diameter spherical solid tumour, simulated by polystyrene, which was located centrally inside lung tissue, simulated by cork. The planned dose distribution was made conformal to the PTV, which was a 15 mm three-dimensional expansion of the tumour. Values of both the absolute dose at the International Commission on Radiation Units and Measurement (ICRU) reference point and relative dose distributions inside the PTV and in the lung were calculated using three inhomogeneity correction algorithms. The algorithms investigated in this study are the pencil beam algorithm with one-dimensional corrections, the modified Batho algorithm and the equivalent path length algorithm. The calculated data were compared with measurements for a simple beam set-up using radiographic film and ionization chambers. Results: For this specific configuration, deviations of up to 3.5% between calculated and measured values of the dose at the ICRU reference point were found. Discrepancies between measured and calculated beam fringe values (distance between the 50 and 90% isodose lines) of up to 14 mm have been observed. The differences in beam fringe and penumbra width (20-80%) increase with increasing beam energy. Our results demonstrate that an underdosage of the PTV up to 20% may occur if calculated dose values are used for treatment planning. The three algorithms predict a considerably higher dose in the lung, both along the central beam axis and in the lateral direction, compared-with the actual delivered dose values. Conclusions: The dose at the ICRU reference point of such a tumour in lung geometry is calculated with acceptable accuracy. Differences between calculated and measured dose distributions are primarily due to changes in electron transport in the lung, which are not adequately taken into account by the simple tissue inhomogeneity correction algorithms investigated in this study. Particularly for high photon beam energies, clinically unacceptable errors will be introduced in the choice of field sizes employed for conformal treatments, leading to underdosage of the PTV. In addition, the dose to the lung will be wrongly predicted which may influence the choice of the prescribed dose level in dose-escalation studies. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:299 / 309
页数:11
相关论文
共 25 条
[1]
A PENCIL BEAM MODEL FOR PHOTON DOSE CALCULATION [J].
AHNESJO, A ;
SAXNER, M ;
TREPP, A .
MEDICAL PHYSICS, 1992, 19 (02) :263-273
[2]
[Anonymous], 1989, TISS SUBST RAD DOS M
[3]
Beam intensity modulation to reduce the field sizes for conformal irradiation of lung tumors: A dosimetric study [J].
Brugmans, MJP ;
van der Horst, A ;
Lebesque, JV ;
Mijnheer, BJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 43 (04) :893-904
[4]
CUNNINGHAM JR, 1982, PROGR MED PHYSICS
[5]
Dosimetric evaluation of a commercial 3-D treatment planning system using Report 55 by AAPM Task Group 23 [J].
Declich, F ;
Fumasoni, K ;
Mangili, P ;
Cattaneo, GM ;
Iori, M .
RADIOTHERAPY AND ONCOLOGY, 1999, 52 (01) :69-77
[6]
PITFALLS IN THE USE OF HIGH-ENERGY X-RAYS TO TREAT TUMORS IN THE LUNG [J].
EKSTRAND, KE ;
BARNES, WH .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (01) :249-252
[7]
EVALUATION OF LUNG DOSE CORRECTION METHODS FOR PHOTON IRRADIATIONS OF THORAX PHANTOMS [J].
ELKHATIB, EE ;
EVANS, M ;
PLA, M ;
CUNNINGHAM, JR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1989, 17 (04) :871-878
[8]
Fraass BA, 1987, USE COMPUTERS RAD TH, P273
[9]
Effect of low-density lateral interfaces on soft-tissue doses [J].
Hunt, MA ;
Desobry, GE ;
Fowble, B ;
Coia, LR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 37 (02) :475-482
[10]
*ICRU, 1987, 42 ICRU