Image quality and localization accuracy in C-arm tomosynthesis-guided head and neck surgery

被引:65
作者
Bachar, G. [3 ]
Siewerdsen, J. H. [1 ,2 ]
Daly, M. J. [1 ]
Jaffray, D. A. [1 ,4 ,5 ]
Irish, J. C. [3 ]
机构
[1] Princess Margaret Hosp, Ontario Canc Inst, Toronto, ON M5G 2M9, Canada
[2] Univ Toronto, Dept Med Biophys, Toronto, ON M5G 2M9, Canada
[3] Univ Toronto, Dept Otolaryngol Head & Neck Surg, Toronto, ON M5G 2M9, Canada
[4] Princess Margaret Hosp, Radiat Med Program, Toronto, ON M5G 2M9, Canada
[5] Univ Toronto, Dept Radiat Oncol, Toronto, ON M5G 2M9, Canada
基金
美国国家卫生研究院;
关键词
image-guided interventions; image-guided surgery; C-arm; tomosynthesis; cone-beam CT; flat-panel detector; image quality;
D O I
10.1118/1.2799492
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
The image quality and localization accuracy for C-arm tomosynthesis and cone-beam computed tomography (CBCT) guidance of head and neck surgery were investigated. A continuum in image acquisition was explored, ranging from a single exposure (radiograph) to multiple projections acquired over a limited arc (tomosynthesis) to a full semicircular trajectory (CBCT). Experiments were performed using a prototype mobile C-arm modified to perform 3D image acquisition (a modified Siemens PowerMobil). The tradeoffs in image quality associated with the extent of the source-detector arc (theta(tot)), the number of projection views, and the total imaging dose were evaluated in phantom and cadaver studies. Surgical localization performance was evaluated using three cadaver heads imaged as a function of theta(tot). Six localization tasks were considered, ranging from high-contrast feature identification (e.g., tip of a K-wire pointer) to more challenging soft-tissue delineation (e.g., junction of the hard and soft palate). Five head and neck surgeons and one radiologist participated as observers. For each localization task, the 3D coordinates of landmarks pinpointed by each observer were analyzed as a function of theta(tot). For all tomosynthesis angles, image quality was highest in the coronal plane, whereas sagittal and axial planes exhibited a substantial decrease in spatial resolution associated with out-of-plane blur and distortion. Tasks involving complex, lower-contrast features demonstrated steeper degradation with smaller tomosynthetic arc. Localization accuracy in the coronal plane was correspondingly high, maintained to <3 mm down to theta(tot)similar to 30 degrees, whereas sagittal and axial localization degraded rapidly below theta(tot)similar to 60 degrees. Similarly, localization precision was better than similar to 1 mm within the coronal plane, compared to similar to 2-3 mm out-of-plane for tomosynthesis angles below theta(tot)similar to 45 degrees. An overall 3D localization accuracy of similar to 2.5 mm was achieved with theta(tot)similar to 90 degrees for most tasks. The high in-plane spatial resolution, short scanning time, and low radiation dose characteristic of tomosynthesis may enable the surgeon to collect near real-time images throughout the procedure with minimal interference to surgical workflow. Therefore, tomosynthesis could provide a useful addition to the image-guided surgery arsenal, providing on-demand, high quality image updates, complemented by CBCT at critical milestones in the surgical procedure. (C) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:4664 / 4677
页数:14
相关论文
共 62 条
[1]
COMPUTER-ASSISTED SURGERY [J].
ADAMS, L ;
KRYBUS, W ;
MEYEREBRECHT, D ;
RUEGER, R ;
GILSBACH, JM ;
MOESGES, R ;
SCHLOENDORFF, G .
IEEE COMPUTER GRAPHICS AND APPLICATIONS, 1990, 10 (03) :43-51
[2]
[Anonymous], [No title captured]
[3]
Image quality in extended arc filtered digital tomosynthesis [J].
Badea, C ;
Kolitsi, Z ;
Pallikarakis, N .
ACTA RADIOLOGICA, 2001, 42 (02) :244-248
[4]
BARRETT H H, 1976, Computers in Biology and Medicine, V6, P307, DOI 10.1016/0010-4825(76)90068-8
[5]
Estimation of the noisy component of anatomical backgrounds [J].
Bochud, FO ;
Valley, JF ;
Verdun, FR ;
Hessler, C ;
Schnyder, P .
MEDICAL PHYSICS, 1999, 26 (07) :1365-1370
[6]
Human observer detection experiments with mammograms and power-law noise [J].
Burgess, AE ;
Jacobson, FL ;
Judy, PF .
MEDICAL PHYSICS, 2001, 28 (04) :419-437
[7]
Endoscopic sinus surgery using intraoperative computed tomography imaging for updating a three-dimensional navigation system [J].
Cartellieri, M ;
Vorbeck, F .
LARYNGOSCOPE, 2000, 110 (02) :292-296
[8]
Application of soft tissue modelling to image-guided surgery [J].
Carter, TJ ;
Sermesant, M ;
Cash, DM ;
Barratt, DC ;
Tanner, C ;
Hawkes, DJ .
MEDICAL ENGINEERING & PHYSICS, 2005, 27 (10) :893-909
[9]
Data analysis for detection and localization of multiple abnormalities with application to mammography -: Authors:: Nancy A.!Obuchowski, PhD, Michael L.!Lieber, MS, Kimerly A.!Powell, PhD -: Publication:: Acad Radiol 2000; 7:516-525 [J].
Chakraborty, DP .
ACADEMIC RADIOLOGY, 2000, 7 (07) :553-554
[10]
DIGITAL AND CONVENTIONAL CHEST IMAGING - A MODIFIED ROC STUDY OF OBSERVER PERFORMANCE USING SIMULATED NODULES [J].
CHAKRABORTY, DP ;
BREATNACH, ES ;
YESTER, MV ;
SOTO, B ;
BARNES, GT ;
FRASER, RG .
RADIOLOGY, 1986, 158 (01) :35-39