Electrophysiological alterations after mechanical circulatory support in patients with advanced cardiac failure

被引:109
作者
Harding, JD [1 ]
Piacentino, V [1 ]
Gaughan, JP [1 ]
Houser, SR [1 ]
Margulies, KB [1 ]
机构
[1] Temple Univ, Sch Med, Cardiovasc Res Grp, Philadelphia, PA 19140 USA
关键词
heart failure; heart-assist device; QT interval; action potential; calcium;
D O I
10.1161/hc3601.095718
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Recognizing that mechanical circulatory support with a left ventricular assist device (LVAD) induces changes in myocardial structure and contractile function, we examined whether there are changes in ventricular conduction and/or repolarization among failing human hearts after LVAD implantation. Methods and Results-We examined 12-lead electrocardiograms before surgery, immediately after LVAD placement, and at a delayed (>1 week) postoperative time point in 23 patients who were receiving LVAD support for refractory heart failure. The immediate effects of hemodynamic unloading via LVAD placement included a decrease in QRS duration from 117+/-6 to 103+/-6 ms (P<0.01), an increase in absolute QT duration from 359+/-6 to 378+/-8 ms (P<0.05), and an increase in the heart rate-corrected QT interval (QTc) from 379+/-10 to 504+/-11 ms (P<0.01). None of these immediate changes were observed among 22 patients undergoing routine coronary artery bypass grafting. With sustained cardiac unloading via LVAD support, there was a marked decrease in the QTc from 504+/-11 to 445+/-9 ms (P<0.001). Studies in isolated cardiac myocytes, obtained at the time of transplantation, confirmed that delayed decreases in heart rate-adjusted QTc were the result of decreases in action potential duration after LVAD support. Conclusions-Acute electrocardiogram responses to LVAD placement demonstrate the dependence of QRS and QT duration on load in the failing human heart. Delayed decreases in QTc and action potential duration reflect reversal of electrophysiologic remodeling in the failing heart. Shortening of the action potential duration likely contributes to the improved cellular contractile performance observed after sustained LVAD support.
引用
收藏
页码:1241 / 1247
页数:7
相关论文
共 32 条
[1]  
Altemose GT, 1997, J HEART LUNG TRANSPL, V16, P765
[2]  
Bartling B, 1999, CIRCULATION, V100, P216
[3]  
Bazett HC, 1920, HEART-J STUD CIRC, V7, P353
[4]   Left ventricular assist device-induced reverse ventricular remodeling [J].
Burkhoff, D ;
Holmes, JW ;
Madigan, J ;
Barbone, A ;
Oz, MC .
PROGRESS IN CARDIOVASCULAR DISEASES, 2000, 43 (01) :19-26
[5]   Swelling-activated chloride current is persistently activated in ventricular myocytes from dogs with tachycardia-induced congestive heart failure [J].
Clemo, HF ;
Stambler, BS ;
Baumgarten, CM .
CIRCULATION RESEARCH, 1999, 84 (02) :157-165
[6]  
de Bruyne MC, 1998, CIRCULATION, V97, P467
[7]  
Depre C, 1999, AM J CARDIOL, V83, p58H
[8]   Myocyte recovery after mechanical circulatory support in humans with end-stage heart failure [J].
Dipla, K ;
Mattiello, JA ;
Jeevanandam, V ;
Houser, SR ;
Margulies, KB .
CIRCULATION, 1998, 97 (23) :2316-2322
[9]   Improved left ventricular function after chronic left ventricular unloading [J].
Frazier, OH ;
Benedict, CR ;
Radovancevic, B ;
Bick, RJ ;
Capek, P ;
Springer, WE ;
Macris, MP ;
Delgado, R ;
Buja, LM .
ANNALS OF THORACIC SURGERY, 1996, 62 (03) :675-681
[10]  
Fridericia LS., 1920, Acta Med Scand, V53, P469, DOI DOI 10.1111/J.0954-6820.1920.TB18266.X