Calibration of the RT3 accelerometer for ambulation and nonambulation in children

被引:37
作者
Chu, Eva Y. W. [1 ]
McManus, Alison M. [1 ]
Yu, Clare C. W. [1 ]
机构
[1] Univ Hong Kong, Inst Human Performance, Hong Kong, Peoples R China
关键词
triaxial accelerometer; physical activity; sedentary; Chinese;
D O I
10.1249/mss.0b013e318148436c
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
CHU, E. Y. W., A. M. McMANUS, and C. C. W YU. Calibration of the RT3 Accelerometer for Ambulation and Nonambulation in Children. Med. Sci. Sports Exerc., Vol. 39, No. 11, pp. 2085-2091, 2007. Purpose: The purpose of this study was to provide RT3 accelerometer thresholds to distinguish nonambulation from ambulation, as well as distinguish between low, moderate, and vigorous intensity ambulation in Chinese children. Methods: Thirty-five 8- to 12-yr-olds completed a laboratory-based experiment to calibrate the RT3 device across a range of intensities. Oxygen uptake during sedentary tasks and ambulation was aligned, with corresponding RT3 output, to one of four intensity categories (sedentary, < 2 METs; low, >= 2 but < 3 METs; moderate, >= 3 but < 6; and vigorous, >= 6). Threshold values were derived using receiver operator curves to distinguish the sedentary from low intensity, low from moderate intensity and moderate from vigorous intensity. These were confirmed in an independent sample of 46 similarly aged children. Results: RT3 movement counts increased in a linear manner with scaled oxygen uptake from stationary to vigorous movement (r(2) = 0.83). The ROC-derived thresholds showed a good ability to discriminate between nonambulatory and ambulatory tasks, as well as distinguish between low, moderate, and vigorous ambulation (sensitivity values of 87-100% and specificity values of 97-100%). ROC analyses in the independent sample showed sensitivity and specificity values ranging from 72 to 98%, indicating that the thresholds provided an accurate distinction between the four intensity categories. A Cohen's kappa of kappa = 0.92 confirmed that the lower threshold had nearperfect agreement with the independent sample, whereas the moderate-intensity and vigorous-intensity thresholds showed good agreement with the independent sample (kappa = 0.63 and 0.65, respectively). Conclusion: The RT3 accelerometer provides an acceptable marker of both sedentary and ambulatory behavior in Chinese children.
引用
收藏
页码:2085 / 2091
页数:7
相关论文
共 45 条
[11]   Calibration of accelerometer output for children [J].
Freedson, P ;
Pober, D ;
Janz, KF .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2005, 37 (11) :S523-S530
[12]   Energy costs of physical activities in children and adolescents [J].
Harrell, JS ;
Mcmurray, RG ;
Baggett, CD ;
Pennell, ML ;
Pearce, PF ;
Bangdiwala, SI .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2005, 37 (02) :329-336
[13]   Commuting, leisure-time physical activity, and cardiovascular risk factors in China [J].
Hu, G ;
Pekkarinen, H ;
Hänninen, O ;
Yu, ZJ ;
Guo, ZY ;
Tian, HG .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2002, 34 (02) :234-238
[14]  
Ji Cheng-ye, 2004, Zhonghua Liu Xing Bing Xue Za Zhi, V25, P103
[15]   Home and recess physical activity of Hong Kong children [J].
Johns, DP ;
Ha, AS .
RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 1999, 70 (03) :319-323
[16]   Physical activity related energy expenditure in children by doubly labeled water as compared with the Caltrac accelerometer [J].
Johnson, RK ;
Russ, J ;
Goran, MI .
INTERNATIONAL JOURNAL OF OBESITY, 1998, 22 (11) :1046-1052
[17]   Leisure time physical activity and mortality in Hong Kong: Case-control study of all adult deaths in 1998 [J].
Lam, TH ;
Ho, SY ;
Hedley, AJ ;
Mak, KH ;
Leung, GM .
ANNALS OF EPIDEMIOLOGY, 2004, 14 (06) :391-398
[18]   Laboratory measurement of posture allocation and physical activity in children [J].
Lanningham-Foster, LM ;
Jensen, TB ;
McCrady, SK ;
Nysse, LJ ;
Foster, RC ;
Levine, JA .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2005, 37 (10) :1800-1805
[19]   Physical inactivity is a disease [J].
Lees, SJ ;
Booth, FW .
Nutrition and Fitness: Mental Health, Aging, and the Implementation of a Healthy Diet and Physical Activity Lifestyle, 2005, 95 :73-79
[20]   Validation of the Tracmor triaxial accelerometer system for walking [J].
Levine, JA ;
Baukol, PA ;
Westerterp, KR .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2001, 33 (09) :1593-1597