Measurement of solution viscosity by atomic force microscopy

被引:65
作者
Ahmed, N [1 ]
Nino, DF [1 ]
Moy, VT [1 ]
机构
[1] Univ Miami, Sch Med, Dept Physiol & Biophys, Miami, FL 33136 USA
关键词
D O I
10.1063/1.1368856
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We report on studies aimed at employing the atomic force microscope (AFM) to measure the viscosity of aqueous solutions. At ambient temperature, the AFM cantilever undergoes thermal fluctuations that are highly sensitive to the local environment. Here, we present measurements of the cantilever's resonant frequency in aqueous solutions of glycerol, sucrose, ethanol, sodium chloride, polyethylene glycol, and bovine plasma albumin. The measurements revealed that variations in the resonant frequency of the cantilever in the different solutions are largely dependent on the viscosity of the medium. An application of this technique is to monitor the progression of a chemical reaction where a change in viscosity is expected to occur. An example is demonstrated through monitoring of the hydrolysis of double stranded deoxyribonucleic acid by DNase I. (C) 2001 American Institute of Physics.
引用
收藏
页码:2731 / 2734
页数:4
相关论文
共 22 条
[1]   A biosensor based on micromechanical interrogation of living cells [J].
Antonik, MD ;
DCosta, NP ;
Hoh, JH .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1997, 16 (02) :66-72
[2]   Discrete interactions in cell adhesion measured by single-molecule force spectroscopy [J].
Benoit, M ;
Gabriel, D ;
Gerisch, G ;
Gaub, HE .
NATURE CELL BIOLOGY, 2000, 2 (06) :313-317
[3]   ATOMIC FORCE MICROSCOPE [J].
BINNIG, G ;
QUATE, CF ;
GERBER, C .
PHYSICAL REVIEW LETTERS, 1986, 56 (09) :930-933
[4]   RESONANCE RESPONSE OF SCANNING FORCE MICROSCOPY CANTILEVERS [J].
CHEN, GY ;
WARMACK, RJ ;
THUNDAT, T ;
ALLISON, DP ;
HUANG, A .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1994, 65 (08) :2532-2537
[5]   A NONDESTRUCTIVE METHOD FOR DETERMINING THE SPRING CONSTANT OF CANTILEVERS FOR SCANNING FORCE MICROSCOPY [J].
CLEVELAND, JP ;
MANNE, S ;
BOCEK, D ;
HANSMA, PK .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (02) :403-405
[6]   AUTOMATED MEASUREMENT OF PLASMA VISCOSITY BY CAPILLARY VISCOMETER [J].
COOKE, BM ;
STUART, J .
JOURNAL OF CLINICAL PATHOLOGY, 1988, 41 (11) :1213-1216
[7]   DIRECT MEASUREMENT OF COLLOIDAL FORCES USING AN ATOMIC FORCE MICROSCOPE [J].
DUCKER, WA ;
SENDEN, TJ ;
PASHLEY, RM .
NATURE, 1991, 353 (6341) :239-241
[8]   Observing single biomolecules at work with the atomic force microscope [J].
Engel, A ;
Müller, DJ .
NATURE STRUCTURAL BIOLOGY, 2000, 7 (09) :715-718
[9]   ADHESION FORCES BETWEEN INDIVIDUAL LIGAND-RECEPTOR PAIRS [J].
FLORIN, EL ;
MOY, VT ;
GAUB, HE .
SCIENCE, 1994, 264 (5157) :415-417
[10]   Force-mediated kinetics of single P-selectin ligand complexes observed by atomic force microscopy [J].
Fritz, J ;
Katopodis, AG ;
Kolbinger, F ;
Anselmetti, D .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1998, 95 (21) :12283-12288