Fast high-performance liquid chromatographic analysis of mianserin and its metabolites in human plasma using monolithic silica column and solid phase extraction

被引:29
作者
Hefnawy, MM [1 ]
Aboul-Enein, HY [1 ]
机构
[1] King Faisal Specialist Hosp & Res Ctr, Pharmaceut Anal Lab, Dept Biol & Med Res, Riyadh 11211, Saudi Arabia
关键词
mianserin and its metabolites; monolithic silica column; solid phase extraction; human plasma;
D O I
10.1016/j.aca.2003.10.058
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fast high-performance liquid chromatography (HPLC) method was developed and validated for the simultaneous determination of mianserin (MIAN) and its metabolites desmethylmianserin (DMM), 8-hydroxymianserin (HM) and mianserin-N-oxide (MNO) in human plasma. Each compound, together with internal standard (propranolol) was extracted from the plasma matrix using solid phase extraction. Chromatographic resolution of the analytes was performed on a Chromolith Speed Rod monolithic silica column (100 mm x 4.6 mm i.d.) under isocratic conditions using a mobile phase of 74:26 (v/v) 25 mM phosphate buffer (pH 5.3 adjusted with phosphoric acid): acetonitrile. The elution of the analytes were monitored at 292 min and conducted at ambient temperature. Because of high column efficiency the mobile phase was pumped at a flow rate of 3.5 ml/min. The total run time of the assay was 5 min. The method was validated over the range of 10-200 ng/ml for MIAN, 10-150 ng/ml for DMM, 20-300 ng/ml for HM and 25-500 ng/ml for MNO. The method proved to be precise (within-run precision ranging from 1.6 to 6.9% R.S.D. and between-run precision ranging from 1.3 to 7.2% R.S.D.) and accurate (within-run accuracies ranged from 1.4 to 6.4% and between-run accuracies ranging from 1.5 to 4.5%). The mean absolute recoveries were 95.7, 94.8, 99.6, and 102.6% for MIAN, DMM, HM and MNO, respectively. The limit of quantitation (LOQ) for MIAN and DMM was 10 ng/ml and for HM and MNO were 20 and 25 ng/ml in human plasma, respectively. The limit of detection (LOD) for MIAN, DMM, HM and MNO was 5, 2.5, 10 and 15 ng/ml, respectively. The described method demonstrates the feasibility for employing monolithic columns to effect rapid bioanalytical HPLC analysis for the quantitative determination of MIAN and its major metabolites in human plasma. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:291 / 297
页数:7
相关论文
共 36 条
[31]   Fast separations on monolithic silica columns: method transfer, robustness and column ageing for some case studies [J].
van Nederkassel, AM ;
Aerts, A ;
Dierick, A ;
Massart, DL ;
Vander Heyden, Y .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 32 (02) :233-249
[32]   SIMPLIFIED METHOD FOR DETERMINATION OF THE TETRACYCLIC ANTI-DEPRESSANT MIANSERIN IN HUMAN-PLASMA USING GAS-CHROMATOGRAPHY WITH NITROGEN DETECTION [J].
VINK, J ;
VANHAL, HJM .
JOURNAL OF CHROMATOGRAPHY, 1980, 181 (01) :25-31
[33]  
WONG SHY, 1984, CLIN CHEM, V30, P230
[34]   High-speed liquid chromatography/tandem mass spectrometry using a monolithic column for high-throughput bioanalysis [J].
Wu, JT ;
Zeng, H ;
Deng, YZ ;
Unger, SE .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (13) :1113-1119
[35]   Application of a chromolith SpeedROD RP-18e HPLC column:: Determination of ochratoxin A in different wines by high-performance liquid chromatography-tandem mass spectrometry [J].
Zöllner, P ;
Leitner, A ;
Lubda, D ;
Cabrera, K ;
Lindner, W .
CHROMATOGRAPHIA, 2000, 52 (11-12) :818-820
[36]   Monolithic stationary phases for liquid chromatography and capillary electrochromatography [J].
Zou, HF ;
Huang, XD ;
Ye, ML ;
Luo, QZ .
JOURNAL OF CHROMATOGRAPHY A, 2002, 954 (1-2) :5-32