A planar microfabricated nanoelectrospray emitter tip based on a capillary slot

被引:31
作者
Le Gac, S
Arscott, S
Rolando, C
机构
[1] Univ Lille 1, Lab Chim Organ & Macromol, CNRS, UPRESA 8009, F-59655 Villeneuve Dascq, France
[2] Inst Elect Microelect & Nanotechnol, Villeneuve Dascq, France
关键词
microfabricated emitter tip; microfluidics; miniaturization; nanoelectrospray ionization;
D O I
10.1002/elps.200305664
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We report on the fabrication and testing of planar nib-like structures for nanoelectrospray ionization-mass spectrometry (nanoESI-MS) applications. The micro-nib structures were fabricated on silicon substrates using the negative photoresist SU-8; they include capillary slots with widths of 8 and 16 pm. A suitable wafer cleaving step made the nib-like structures overhang the edge of a silicon substrate to provide a robust interface for nanoESI-MS applications; this freeing of the nib tip from the wafer surface created a point-like structure that is essential to establish an electrospray. The micro-nib sources were successfully tested on an LCQ Deca XP+ ion trap mass spectrometer using peptide samples at concentrations down to 1 mum. The high voltage was applied using a platinum wire inserted in the sample reservoir upstream to the capillary slot. A Taylor cone was clearly seen at the nib tip. The micro-nibs performed well at voltages as low as 0.8 kV; such performances are state-of-the-art with respect to current micromachined ESI-MS interfaces and are conditions comparable to those used for standard emitter tips. In addition, we clearly observed the influence of the micro-nib slot width on the ionization performances: the narrower the slot, the better the performances.
引用
收藏
页码:3640 / 3647
页数:8
相关论文
共 56 条
[1]   A mass spectrometric journey into protein and proteome research [J].
Aebersold, R .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2003, 14 (07) :685-695
[2]   Mass spectrometry in proteomics [J].
Aebersold, R ;
Goodlett, DR .
CHEMICAL REVIEWS, 2001, 101 (02) :269-295
[3]   Mass spectrometry-based proteomics [J].
Aebersold, R ;
Mann, M .
NATURE, 2003, 422 (6928) :198-207
[4]   Functional genomics by mass spectrometry [J].
Andersen, JS ;
Mann, M .
FEBS LETTERS, 2000, 480 (01) :25-31
[5]   Micro total analysis systems. 2. Analytical standard operations and applications [J].
Auroux, PA ;
Iossifidis, D ;
Reyes, DR ;
Manz, A .
ANALYTICAL CHEMISTRY, 2002, 74 (12) :2637-2652
[6]   Plastic advances microfluidic devices. [J].
Boone, T ;
Fan, ZH ;
Hooper, H ;
Ricco, A ;
Tan, HD ;
Williams, S .
ANALYTICAL CHEMISTRY, 2002, 74 (03) :78A-86A
[7]   Analysis of peptides using partial (no discharge) atmospheric pressure chemical ionization conditions with ion trap mass spectrometry [J].
Cristoni, S ;
Bernardi, LR ;
Biunno, I ;
Guidugli, F .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (17) :1686-1691
[8]   THE CURRENT EMITTED BY HIGHLY CONDUCTING TAYLOR CONES [J].
DELAMORA, JF ;
LOSCERTALES, IG .
JOURNAL OF FLUID MECHANICS, 1994, 260 :155-184
[9]  
DESAI A, 1997, INT C SOL STAT SENS
[10]   MICRO-ELECTROSPRAY MASS-SPECTROMETRY - ULTRA-HIGH-SENSITIVITY ANALYSIS OF PEPTIDES AND PROTEINS [J].
EMMETT, MR ;
CAPRIOLI, RM .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (07) :605-613