Developments in component-based normalization for 3D PET

被引:73
作者
Badawi, RD [1 ]
Marsden, PK [1 ]
机构
[1] Kings Coll London, Guys & St Thomas Clin PET Ctr, Div Radiol Sci & Med Engn, London WC2R 2LS, England
关键词
D O I
10.1088/0031-9155/44/2/020
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Normalization in positron emission tomography (PET) is the process of ensuring that all lines of response joining detectors in coincidence have the same effective sensitivity. In three dimensional (3D) PET, normalization is complicated by the presence of a large proportion of scattered coincidences, and by the fact that cameras operating in 3D mode encounter a very wide range of count-rates. In this work a component-based normalization model is presented which separates the normalization of true and scattered coincidences and accounts for variations in normalization effects with count-rate. The effects of the individual components in the model on reconstructed images are investigated, and it is shown that only a subset of these components has a significant effect on reconstructed image quality.
引用
收藏
页码:571 / 594
页数:24
相关论文
共 26 条
[1]   Algorithms for calculating detector efficiency normalization coefficients for true coincidences in 3D PET [J].
Badawi, RD ;
Lodge, MA ;
Marsden, PK .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (01) :189-205
[2]   Optimization of noise-equivalent count rates in 3D PET [J].
Badawi, RD ;
Marsden, PK ;
Cronin, BF ;
Sutcliffe, JL ;
Maisey, MN .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (09) :1755-1776
[3]  
BADAWI RD, 1998, THESIS U LONDON
[4]  
BADAWI RD, 1999, IN RPESS 1998 IEEE N
[5]  
Bailey DL, 1998, DEV NUC MED, V32, P55
[6]   An investigation of factors affecting detector and geometric correction in normalization of 3-D PET data [J].
Bailey, DL ;
Townsend, DW ;
Kinahan, PE ;
Grootoonk, S ;
Jones, T .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (06) :3300-3307
[7]  
Casey M. E., 1995, Proceedings of the 1995 International Meeting on Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine, P67
[8]   QUANTITATION IN POSITRON EMISSION COMPUTED-TOMOGRAPHY .7. A TECHNIQUE TO REDUCE NOISE IN ACCIDENTAL COINCIDENCE MEASUREMENTS AND COINCIDENCE EFFICIENCY CALIBRATION [J].
CASEY, ME ;
HOFFMAN, EJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (05) :845-850
[9]   EFFECTS OF SCATTER ON MODEL PARAMETER ESTIMATES IN 3D PET STUDIES OF THE HUMAN BRAIN [J].
CHERRY, SR ;
HUANG, SC .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) :1174-1179
[10]   3D PET USING A CONVENTIONAL MULTISLICE TOMOGRAPH WITHOUT SEPTA [J].
CHERRY, SR ;
DAHLBOM, M ;
HOFFMAN, EJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (04) :655-668