Immunoscintigraphy of septic loosening of knee endoprosthesis: a retrospective evaluation of the antigranulocyte antibody BW 250/183

被引:30
作者
Klett, R
Kordelle, J
Stahl, U
Khalisi, A
Puille, M
Steiner, D
Bauer, R
机构
[1] Univ Hosp Giessen, Clin Nucl Med, D-35385 Giessen, Germany
[2] Univ Hosp Giessen, Orthoped Clin, Giessen, Germany
[3] Univ Hosp Giessen, Dept Pathol, Giessen, Germany
关键词
knee prosthesis; infection; septic loosening; immunoscintigraphy; antigranulocyte antibody;
D O I
10.1007/s00259-003-1275-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Immunoscintigraphy with the use of the antigranulocyte antibody BW 250/183 is a reliable method for detecting infection, especially in septic loosening of hip prostheses, for which purpose quantitative interpretation of the time-activity course is employed. Therefore, we retrospectively studied whether similar results could be achieved in knee prostheses. We verified 28 scintigraphic examinations in 26 patients by histology. Scintigraphy was performed during an early (4-6 h post injection) and a late phase (23-25 h post injection). Infection was diagnosed when activity around the knee prosthesis increased by more than 10% compared with bone marrow. We found a sensitivity and a negative predictive value of 100%, a specificity of 80%, a positive predictive value of 81% and an accuracy of 89%. Specificity and accuracy are lower than in the evaluation of hip prostheses; however, in comparison to other scintigraphic modalities, scintigraphy with the antigranulocyte antibody BW 250/183 is superior in excluding infection and has better specificity and accuracy. Therefore, as in the case of hip prostheses, the described methodology appears to be the scintigraphic modality of choice for knee prostheses.
引用
收藏
页码:1463 / 1466
页数:4
相关论文
共 17 条
[1]
BERBERICH R, 1992, NUKLEARMED, V31, P70
[2]
IMMUNOSCINTIGRAPHY WITH ANTIGRANULOCYTE MONOCLONAL-ANTIBODIES FOR THE DIAGNOSIS OF SEPTIC LOOSENING OF HIP PROSTHESES [J].
BOUBAKER, A ;
DELALOYE, AB ;
BLANC, CH ;
DUTOIT, M ;
LEYVRAZ, PF ;
DELALOYE, B .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1995, 22 (02) :139-147
[3]
Imaging of low-grade bone infection with a technetium-99m labelled monoclonal anti-NCA-90 Fab' fragment in patients with previous joint surgery [J].
Ivanèeviæ, V ;
Perka, C ;
Hasart, O ;
Sandrock, D ;
Munz, DL .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (04) :547-551
[4]
Efficacy of combined technetium-99m sulfur colloid/indium-111 leukocyte scans to detect infected total hip and knee arthroplasties [J].
Joseph, TN ;
Mujtaba, M ;
Chen, AL ;
Maurer, SL ;
Zuckerman, JD ;
Maldjian, C ;
Di Cesare, PE .
JOURNAL OF ARTHROPLASTY, 2001, 16 (06) :753-758
[5]
Kaim A, 1997, EUR J NUCL MED, V24, P732
[6]
Serial diagnosis of septic loosening of hip-endoprosthesis using laboratory parameters and antigranulocytescintigraphy. [J].
Klett, R ;
Khalisi, A ;
Haas, H ;
Puille, M ;
Steiner, D ;
Stürz, H ;
Bauer, R .
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2001, 139 (05) :415-419
[7]
Klett R, 2001, NUKLEARMED-NUCL MED, V40, P75
[8]
99mTc-ciprofloxacin (Infecton) imaging in the diagnosis of knee prosthesis infections [J].
Larikka, MJ ;
Ahonen, AK ;
Niemelä, O ;
Puronto, O ;
Junila, JA ;
Hämäläinen, MM ;
Britton, K ;
Syrjälä, HP .
NUCLEAR MEDICINE COMMUNICATIONS, 2002, 23 (02) :167-170
[9]
Role of nuclear medicine in diagnosis of the infected joint replacement [J].
Love, C ;
Tomas, MB ;
Marwin, SE ;
Pugliese, PV ;
Palestro, CJ .
RADIOGRAPHICS, 2001, 21 (05) :1229-1238
[10]
MIRRA JM, 1982, CLIN ORTHOP RELAT R, P175